Determination of ammonium in seawater by column-switching ion chromatography.

نویسندگان

  • Y Huang
  • S F Mou
  • J M Riviello
چکیده

A system which combines column switching and concentration was developed. A binary eluent mechanism was developed to study the effect of high sample concentration matrix on retention time shifts of the trace analyte. Separation conditions were chosen according to this mechanism to reduce the retention time shift of ammonium in the presence of high concentration sodium ion: high concentration sulfuric acid (25 mmol/l) was used as the eluent, and a hydronium-selective column of high capacity--a CS12 column, was employed. Since the retention time shift was reduced, the interval between onset and the complete elution of a high concentration ammonium standard (10 mg/l) was directly defined as the column-switching time window, which greatly simplified the procedure for determining the time window. Results showed that for ammonium below 1 mg/l, 90% ammonium was introduced and concentrated. Detection limits of 12.8 microg/l were obtained for ammonium with sodium at 1000 mg/l.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of an Ion Chromatography Method for Quantification of Ammonium Ions in STEALTH® Liposomes

Ammonium sulfate is one of the subsidiary components in the stealth liposome structure. The ratio of ammonium ion bound to liposome sphere to ammonium ions outside the liposome plays an important role in drug delivery formulation; accordingly, in order to quantify the ammonium ion in the liposome structure, a rapid and sensitive method was validated using a conductivity detector. Through this m...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Chemiluminescence nitrogen detection in ion chromatography for the determination of nitrogen-containing anions.

Chemiluminescence nitrogen detection (CLND) provides equimolar response for nitrogen-containing ions such as nitrate, nitrite, cyanide, ammonium and tetradecyltrimethylammonium. Only azide yields a lower response. Nitrite, azide and nitrate are separated on a Dionex AS11 column using 5 nM NaOH as eluent with a 3 microM (1 ng N) limit of detection. Matrices, such as 1:10 diluted seawater, do not...

متن کامل

Simultaneous Determination of Celecoxib, Erlotinib, and its Metabolite Desmethyl-Erlotinib (OSI-420) in Rat Plasma by Liquid chromatography/Tandem Mass Spectrometry with Positive/Negative Ion-Switching Electrospray Ionisation

A new method for the simultaneous determination of celecoxib, erlotinib, and its active metabolite desmethyl-erlotinib (OSI-420) in rat plasma, by liquid chromatography/tandem mass spectrometry with positive/negative ion-switching electrospray ionization mode, was developed and validated. Protein precipitation with methanol was selected as the method for preparing the samples. The analytes were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 868 2  شماره 

صفحات  -

تاریخ انتشار 2000