Accurate cytogenetic biodosimetry through automated dicentric chromosome curation and metaphase cell selection
نویسندگان
چکیده
Accurate digital image analysis of abnormal microscopic structures relies on high quality images and on minimizing the rates of false positive (FP) and negative objects in images. Cytogenetic biodosimetry detects dicentric chromosomes (DCs) that arise from exposure to ionizing radiation, and determines radiation dose received based on DC frequency. Improvements in automated DC recognition increase the accuracy of dose estimates by reclassifying FP DCs as monocentric chromosomes or chromosome fragments. We also present image segmentation methods to rank high quality digital metaphase images and eliminate suboptimal metaphase cells. A set of chromosome morphology segmentation methods selectively filtered out FP DCs arising primarily from sister chromatid separation, chromosome fragmentation, and cellular debris. This reduced FPs by an average of 55% and was highly specific to these abnormal structures (≥97.7%) in three samples. Additional filters selectively removed images with incomplete, highly overlapped, or missing metaphase cells, or with poor overall chromosome morphologies that increased FP rates. Image selection is optimized and FP DCs are minimized by combining multiple feature based segmentation filters and a novel image sorting procedure based on the known distribution of chromosome lengths. Applying the same image segmentation filtering procedures to both calibration and test samples reduced the average dose estimation error from 0.4 Gy to <0.2 Gy, obviating the need to first manually review these images. This reliable and scalable solution enables batch processing for multiple samples of unknown dose, and meets current requirements for triage radiation biodosimetry of high quality metaphase cell preparations.
منابع مشابه
Accurate cytogenetic biodosimetry through automated dicentric
Accurate digital image analysis of abnormal microscopic structures relies on high quality images and on minimizing the rates of false positive (FP) and negative objects in images. Cytogenetic biodosimetry detects dicentric chromosomes (DCs) that arise from exposure to ionizing radiation, and determines radiation dose received based on DC frequency. Improvements in automated DC recognition incre...
متن کاملRadiation Dose Estimation by Automated Cytogenetic Biodosimetry.
The dose from ionizing radiation exposure can be interpolated from a calibration curve fit to the frequency of dicentric chromosomes (DCs) at multiple doses. As DC counts are manually determined, there is an acute need for accurate, fully automated biodosimetry calibration curve generation and analysis of exposed samples. Software, the Automated Dicentric Chromosome Identifier (ADCI), is presen...
متن کاملExpedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Biological radiation dose can be estimated from dicentric chromosome frequencies in metaphase cells. Performing these cytogenetic dicentric chromosome assays is traditionally a manual, labor-intensive process not well suited to handle the volume of samples which may require examination in the wake of a mass casualty event. Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) soft...
متن کاملEstablishing cytogenetic biodosimetry laboratory in Saudi Arabia and producing preliminary calibration curve of dicentric chromosomes as biomarker for medical dose estimation in response to radiation emergencies
In cases of public or occupational radiation overexposure and eventual radiological accidents, it is important to provide dose assessment, medical triage, diagnoses and treatment to victims. Cytogenetic bio-dosimetry based on scoring of dicentric chromosomal aberrations assay (DCA) is the "gold standard" biotechnology technique for estimating medically relevant radiation doses. Under the auspic...
متن کاملWHO 1st consultation on the development of a global biodosimetry laboratories network for radiation emergencies (BioDoseNet).
The World Health Organization (WHO) held a consultation meeting at WHO Headquarters, Geneva, Switzerland, December 17-18, 2007, to develop the framework for a global biodosimetry network. The WHO network is envisioned to enable dose assessment using multiple methods [cytogenetics, electron paramagnetic resonance (EPR), radionuclide bioassays, etc.]; however, the initial discussion focused on th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2017