Comparison of platelet glass bead retention techniques in patients with clinical bleeding disorders.

نویسندگان

  • T A Ruma
  • P Mintz
  • F R Davey
  • M Stuart
  • D A Nelson
چکیده

Platelet glass bead retention by the Salzman and infusion pump techniques were compared in 36 control individuals, 10 patients with von Willebrand's syndrome and four patients with thrombocytopathies. No significant differences between the results of the two assays were observed. Eleven percent or less of the control individuals had diminished platelet glass bead retention. The mean percentage platelet retention of the von Willebrand's group and the thrombocytopathy group was less than the mean platelet retention of the control group. However, at least 50 percent of the patients with von Willebrand's syndrome had normal platelet retention by both methods. In the thrombocytopathy group, glass bead retention was more consistently diminished. Although an inverse correlation existed between the duration of bleeding time and the platelet retention assays, consistently diminished platelet retention results were observed only when the bleeding time was 18 minutes or longer. It has been concluded by us that while the glass bead retention assays may be helpful in characterizing certain types of platelet disorders, they are not useful screening assays in the diagnosis of von Willebrand's syndrome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship of platelet retention in glass bead columns to the rate of aggregation with adenosine diphosphate and thrombin.

The initial rate of platelet aggregation induced by adenosine diphosphate and thrombin correlated with the number of platelets retained when samples of citrated blood from the same normal donors were passed through glass bead columns. The results support the view that the glass bead column method of measuring platelet ;adhesiveness' is influenced by platelet aggregation.

متن کامل

Retention of platelets by glass bead filters.

Whole blood was passed through glass bead filters and the retention of platelets studied under various experimental conditions. Platelet retention was similar over a wide range of blood flow rates; however, it was decreased at fast rates of flow. Platelet retention was not influenced by the haematocrit value of the blood over a wide range. Retention in filters containing siliconized beads was s...

متن کامل

Intermediate syndrome of platelet dysfunction.

We studied eight patients with intermittent bleeding episodes usually following trauma and associated with the ingestion of medicine known to interfere with platelet function. All patients had a normal or minimally prolonged baseline bleeding time. All had a normal platelet count, glass bead retention test, and platelet serotonin content and a variable pattern of abnormalities in prothrombin co...

متن کامل

A clinical and experimental study of platelet function in chronic renal failure.

Coagulation and platelet function studies were performed on 24 normal subjects and 29 patients with chronic renal failure due to various causes. Thrombocytopenia was uncommon in the uraemic patients but there was reduced platelet retention in glass bead columns and platelet aggregation with adenosine diphosphate (ADP) and thrombin was slower and less complete than normal. The rate of platelet d...

متن کامل

Guanidinosuccinic acid on human platelet. Effects of exogenous urea, creatinine, and aggregation in vitro.

Patients with severe uremia may have a bleeding tendency associated with a prolonged bleeding time and an adequate platelet count. We have tested the effects on platelet aggregation of three compounds that are found in increased concentration in the blood of patients with renal failure. The addition of urea was followed by an immediate, but transient, increase in optical density of platelet-ric...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 1979