Comparison of compressive forces caused by various cannulated cancellous screws used in arthroscopic ankle arthrodesis

نویسندگان

  • Satoshi Kamijo
  • Tsukasa Kumai
  • Shogo Tanaka
  • Tsuyoshi Mano
  • Yasuhito Tanaka
چکیده

BACKGROUND When performing arthroscopic ankle arthrodesis for end-stage ankle arthritis, internal fixation is performed using bone screws after appropriate preparation. However, optimal characteristics of bone screws have not been examined in terms of pressure force. Objective comparisons of bone-screw performance may provide information on procedures for arthroscopic ankle arthrodesis. The study objectives were to determine whether it was possible to measure compressive force changes using the newly developed device and to infer all screw characteristics from measurement results when used in actual surgeries. In addition, we performed experiments on cadavers to verify whether the experimental results could be applied to the joints of living subjects. METHODS Three types of screws (S1, S2, and S3) were inserted into the unique measurement device, and the changes in pressure were measured for each 45° turn. Changes in pressure and maximum pressure force were recorded after the application of the screws. After reaching the maximum pressure in the simulated bone, further screw rotations were accompanied by a gradual pressure decrease to 0 MPa. We also measured pressure changes in a similar manner by inserting a miniature pressure sensor into the talocrural joints of cadavers. RESULTS The mean maximum pressure ± standard deviation for S1, S2, and S3 were 0.832 ± 0.164 MPa, 0.434 ± 0.116 MPa, and 0.414 ± 0.127 MPa, respectively. Pressure slopes to the maximum did not significantly differ between the screws in the simulated bone, and a subsequent pressure decrease to 0 MPa was significantly more rapid for S1 than for S2 and S3. Although pressure failure after the overtightening of screws was only observed in the simulated bone, patterns of pressure vs. rotation angle were similar in simulated and cadaveric bones. The pressure profile characteristics of three different screw types were determined. CONCLUSIONS We were able to measure the compressive force changes using the newly developed device when the screws were inserted. On the basis of the measurement results, we were able to infer the characteristics of all screws when used in actual surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.

BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint ar...

متن کامل

Arthroscopic arthrodesis for ankle arthritis without bone graft

BACKGROUND Ankle arthrodesis is considered by many to be the standard operative treatment for end-stage ankle arthritis. The purpose of this study was to perform a new technique for ankle joint surface and determine the outcome for the union rates of ankle arthroscopic arthrodesis. METHODS A total of 68 patients with posttraumatic arthritis, primary osteoarthritis, and rheumatoid arthritis we...

متن کامل

Lisfranc arthrodesis for chronic pain: a cannulated screw technique.

Nine patients with injury to the tarsometatarsal joint underwent fusion with cannulated screw fixation after conservative treatment had failed. Symptoms consisted of localized pain, forefoot abduction, and progressive collapse of the medical column. Early diagnosis and treatment were associated with a better functional outcome. The technique involved either a single or double incisional approac...

متن کامل

Letter to the Editor: Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study.

PURPOSE To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. METHODS 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55º and 63º (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated s...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...