The Effect of mode of delivery on the umbilical artery pH

نویسندگان

  • Roya Rahimi
  • Zahra Akbarian
  • Yadollah Zahed Pasha
  • Mohsen Haghshenas Mojaveri
  • Mohsen Haghshenas
چکیده

Background: Abnormal umbilical cord pH can be indicated a distress imposed of newborn and can also be useful in determining the prognosis of the newborn. There are different views about the effect of the neonatal delivery method on the blood gas analysis of the umbilical artery. This study aimed to determine the effect of the method of delivery on umbilical artery pH. Methods: In this Cross-Sectional study, 150 singleton newborns of 37 to 42 weeks, with birth weight 2500 to 4000 g, were allocated. The samples were calculated for values, based on similar studies, and were divided into two groups, including vaginal delivery and caesarian section under spinal anesthesia which have the least difference in pH. Umbilical artery blood gas analysis of both groups were studied. Finally, using statistical T-test for the quantitative data and chi-square for the qualitative data, hypotheses were answered. P-value less than 0.05 was considered statistically significant. Results: Average gestational age was between 39±0.9 weeks and 76 (50.6%) and 74 (49.4%) of neonates were male and female respectively. The average birth weight was 3368.7±473.5 g. In this study, average umbilical artery pH at birth by vaginal delivery and by cesarean section was 7.25±0.06, 7.26 ±0.06 respectively (P>0.05). In this study, in both groups significant differences were seen in all the blood gas values except the umbilical cord artery pH. Conclusions: Our study showed that the pH level of umbilical artery blood was in normal range among newborns of both groups, but Po2 and Pco2 were more appropriate in vaginal deliveries. Due to the prognostic value of umbilical artery PH and the essentiality of prognosis in the newborns under stress, we recommend that this study should be done in the emergency situation, too.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of mode of delivery on the umbilical artery pH

Background: Abnormal umbilical cord pH can be indicated a distress imposed of newborn and can also be useful in determining the prognosis of the newborn. There are different views about the effect of the neonatal delivery method on the blood gas analysis of the umbilical artery. This study aimed to determine the effect of the method of delivery on umbilical artery pH. Methods: In this Cross ...

متن کامل

ارتباط بین نوع زایمان و اسیدمی خون بند ناف نوزادان متولد شده در زایشگاه آیت‌الله کاشانی‌ کرمان

Relationship Between Mode of Delivery and Umbilical Cord Acidemia in Neonates Born at Ayatollah Kashani Hospital, (Kerman) F. Aminzadeh MD Received: 19/07/06 Sent for Revision: 06/11/06 Received Revised Manuscript: 15/11/06 Accepted: 20/12/06 Background and objective: The pH of umbilical cord blood is a useful parameter for health status assessment of neonates. They may be premanentl...

متن کامل

بررسی تأثیر تجویز اکسیژن به مادر در مرحله دوم زایمان بر روی گازهای خون بند ناف

This study was conducted to assess the role of maternal oxygen    administration during the second stage of labor on umbilical cord blood gas    values.  This study was done in Fatemieh hospital on 160 pregnant women    who were admitted for vaginal delivery and had the inclusion criteria.           A group ...

متن کامل

P-247: To Evaluate The Oxytocin Effect on Maternal-Fetal Circulation during Termination of Pregnancy

Background: To evaluate the effect of oxytocin on blood circulation of fetus and uterus by Doppler ultrasound. Materials and Methods: Forty six pregnant women were assigned to receive for indication of delivery intravenous oxytocin. Doppler velocitometry before and after administration of oxytocin for umbilical,middle cerebral artery and uterine artery were performed, and Pulsatility index (PI)...

متن کامل

The relationship between umbilical artery blood gas analysis and Apgar scores in neonates

  Extended Abstract Introduction and Background : in the first minutes of life it’s important to assess newborn condition very fast but effective and decide about medical intervention as needed. Umbilical artery blood gas analysis and Apgar scoring are the most common assessment systems which studies are trying to more sensitive and accurate way.in this study we compare Apgar scoring system an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016