Spatiotemporal dynamics of the BOLD fMRI signals: toward mapping submillimeter cortical columns using the early negative response.
نویسندگان
چکیده
The existence of the early-negative blood-oxygenation-level-dependent (BOLD) response is controversial and its practical utility for mapping brain functions with columnar spatial specificity remains questionable. To address these issues, gradient-echo BOLD fMRI studies were performed at 4.7 T and 9.4 T using the well-established orientation column model in the cat visual cortex. A robust transient early-negative BOLD response was consistently observed in anesthetized cat (-0.35 +/- 0.09%, mean +/- SD, n = 8 at 2.9 +/- 0.5 sec poststimulus onset for 4.7 T, TE = 31 ms; -0.29 +/- 0.10%, n = 4 at 3.0 +/- 0.8 sec poststimulus onset for 9.4 T, TE = 12 ms). In addition to its temporal evolution, the BOLD response also evolved dynamically in the spatial domain. The initially spatially localized early-negative signal appeared to dynamically drain from the active sites toward large vessels, followed by a wave of the delayed positive signal, which exhibited similar spatiotemporal dynamics. Only the early-negative BOLD response within 2 sec of the stimulus onset (not the entire dip) yielded columnar layouts without differential subtraction. The functional maps of two orthogonal orientations using the first 2-sec dip were indeed complementary. On the other hand, the delayed positive BOLD response appeared diffused and extended beyond the active sites. It was thus less suitable to resolve columnar layouts. These results have implications for the design and interpretation of the BOLD fMRI at columnar resolution. Magn Reson Med 44:231-242, 2000.
منابع مشابه
Mapping cortical columnar structures using fMRI.
Mapping cortical columnar structures is important to understand cortical information processing. To map submillimeter columnar structures noninvasively, we have evaluated various functional magnetic resonance imaging (fMRI) techniques using a well-established feline orientation column model. The conventional positive blood oxygenation level-dependent (BOLD) signal is widespread and diffuse due ...
متن کاملSpatiotemporal characteristics and vascular sources of neural-specific and -nonspecific fMRI signals at submillimeter columnar resolution
The neural specificity of hemodynamic-based functional magnetic resonance imaging (fMRI) signals is dependent on both the vascular regulation and the sensitivity of the applied fMRI technique to different types and sizes of blood vessels. In order to examine the specificity of MRI-detectable hemodynamic responses, submillimeter blood oxygenation level-dependent (BOLD) and cerebral blood volume ...
متن کاملAn fMRI study of human visual cortex in response to spatiotemporal properties of visual stimuli
ABSTRACT Background: The brain response to temporal frequencies (TF) has been already reported, but with no study reported for different TF with respect to various spatial frequencies (SF). Materials and Methods: fMRI was performed by 1.5T GE-system in 14 volunteers during checkerboard, with TFs of 4, 6, 8 and 10Hz in low and high SFs of 0.5 and 8cpd. Results: Average percentage BOLD signa...
متن کاملHigh-resolution fMRI maps of cortical activation in nonhuman primates: correlation with intrinsic signal optical images.
One of the most widely used functional brain mapping tools is blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI). This method has contributed to new understandings of the functional roles of different areas in the human brain. However, its ability to map cerebral cortex at high spatial (submillimeter) resolution is still unknown. Other methods such as single- and m...
متن کاملNeural interpretation of blood oxygenation level-dependent fMRI maps at submillimeter columnar resolution.
Whether conventional gradient-echo (GE) blood oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is able to map submillimeter-scale functional columns remains debatable mainly because of the spatially nonspecific large vessel contribution, poor sensitivity and reproducibility, and lack of independent evaluation. Furthermore, if the results from optical imaging of in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 44 2 شماره
صفحات -
تاریخ انتشار 2000