Development of a permeation panel to test dermal protective clothing against sprayed coatings.

نویسندگان

  • Diana M Ceballos
  • Michael G Yost
  • Stephen G Whittaker
  • Carolyn Reeb-Whitaker
  • Janice Camp
  • Russell Dills
چکیده

OBJECTIVES Design, construct, and characterize an apparatus to evaluate dermal protective clothing for resistance to polymerizing materials. Specifically, we evaluated the permeation of the most common glove material used in automotive collision repair (0.10-0.13 mm or 4-5 mil latex) with representative isocyanate-containing clear coats. Our ultimate goal is to make informed recommendations on dermal protective materials to prevent isocyanate exposures and reduce the likelihood of occupational illness in automotive collision repair and other industries. METHODS A novel permeation panel was developed to assess dermal protective clothing. With this apparatus, up to eight test materials may be evaluated under typical-spray application conditions. Solid collection media comprised of 1-(2-pyridyl)-piperazine (2-PP)-coated fiberglass filters or colorimetric SWYPE™ pads were placed behind test materials to capture permeants. The 2-PP-coated filters were subsequently analyzed using a modified OSHA42/PV2034 method. Color change in the SWYPEs provided an immediate field estimate of breakthrough time. In addition, Teflon filters were mounted proximal to the permeation cells to measure the mass of clear coat applied to the panel and to evaluate loading homogeneity. This study evaluated the permeation of isocyanates through 0.10-0.13 mm latex glove material at a fixed time (30 min post-spraying) and over a time course (6-91 min post-spraying). RESULTS Monomers 1,6-hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI) permeated through (0.10-0.13 mm) latex glove material under typical glove use conditions (30 min). The latex glove material exhibited immediate breakthrough, with a permeation rate of 2.9 ng min(-1) cm(-2). The oligomeric forms of HDI and IPDI did not permeate the latex glove material. The spray application at 71 ± 5 °F was fairly homogeneous (33.7 ± 8 mg weight of dry clear coat per 5 cm(2)). CONCLUSIONS The permeation panel is a viable method to assess dermal protective clothing performance against polymerizing materials. Thin (0.10-0.13 mm) latex gloves were determined to be ineffective barriers to the isocyanates commonly found in clear coats. Because this type of glove is used frequently in auto body shops, the potential for isocyanate exposure is of concern. Permeation tests with other dermal protective clothing materials and other clear coat formulations are needed to make recommendations about alternative materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Penetration Test Method: Protection Efficiency of Glove and Clothing Materials Against

Reported cases of allergic contact dermatitis caused by methylenediphenyl diisocyanate (MDI) have increased and thereby increased the need for adequate skin protection. Current standardized permeation and penetration test methods give information about efficacy of protective materials against individual components of the polyurethane systems. They do not give information of what kind of clothin...

متن کامل

Development of a new test cell to measure cumulative permeation of water-insoluble pesticides with low vapor pressure through protective clothing and glove materials

A collaborative approach, involving resources and expertise from several countries, was used to develop a test cell to measure cumulative permeation by a solid-state collection technique. The new technique was developed to measure the permeation of pesticide active ingredients and other chemicals with low vapor pressure that would otherwise be difficult to test via standard techniques. The deve...

متن کامل

Permeation tests of glove and clothing materials against sensitizing chemicals using diphenylmethane diisocyanate as an example.

Diphenylmethane diisocyanate (MDI) is a sensitizing chemical that can cause allergic contact dermatitis and asthma. Protective gloves and clothing are necessary to prevent skin exposure. Breakthrough times are used for the selection of chemical protective gloves and clothing. In the EN 374-3:2003 European standard, breakthrough time is defined as the time in which the permeation reaches the rat...

متن کامل

Solid Particle Erosion of Thermal Sprayed Coatings

Solid particle erosion is an important material degradation mechanism. Although various methods of coating are tried and used for protection against erosion, thermal sprayed coating for such purpose is the most widely used method. In this chapter, evolution of thermal sprayed coating, erosion testing methods, and erosive wear of thermal sprayed coatings are discussed extensively with emphasis o...

متن کامل

Resistance of gloves and protective clothing materials to permeation of cytostatic solutions.

OBJECTIVES The objective of the work was to determine the resistance of selected protective clothing and glove materials to permeation of cytostatics such as docetaxel, fluorouracil, and doxorubicin. MATERIAL AND METHODS The following glove materials were used: natural rubber latex (code A), acrylonitrile-butadiene rubber (code B) and chloroprene rubber (code C). In addition, we tested a laye...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 2011