Digital Simulation of the Generalized Unified Power Flow Controller System with 60-Pulse GTO-Based Voltage Source Converter

نویسنده

  • Rakhmad Syafutra Lubis
چکیده

The Generalized Unified Power Flow Controller (GUPFC) is a Voltage Source Converter (VSC) based Flexible AC Transmission System (FACTS) controller for shunt and series compensation among the multiline transmission systems of a substation. The paper proposes a full model comprising of 60pulse Gate Turn-Off thyristor VSC that is constructed becomes the GUPFC in digital simulation system and investigates the dynamic operation of control scheme for shunt and two series VSC for active and reactive power compensation and voltage stabilization of the electric grid network. The complete digital simulation of the shunt VSC operating as a Static Synchronous Compensator (STATCOM) controlling voltage at bus and two series VSC operating as a Static Synchronous Series Capacitor (SSSC) controlling injected voltage, while keeping injected voltage in quadrature with current within the power system is performed in the MATLAB/Simulink environment using the Power System Blockset (PSB). The GUPFC, control system scheme and the electric grid network are modeled by specific electric blocks from the power system block set. The controllers for the shunt VSC and two series VSCs are presented in this paper based on the decoupled current control strategy. The performance of GUPFC scheme connected to the 500-kV grid is evaluated. The proposed GUPFC controller scheme is fully validated by digital simulation. Keywords— 60-pulse GTO thyristor model VSC, UPFC, GUPFC, active and reactive compensation, voltage stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible Power Electronic Transformer for Power Flow Control Applications

This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...

متن کامل

Unified Power Flow Controller for Power Quality Improvement

— The Unified Power Flow Controller (UPFC) is a typical FACTS (Flexible AC Transmission Systems) device that is the most sophisticated and complex power electronic equipment and has emerged for the control and optimization of power flow and also to regulate the voltage in electrical power transmission system. This project propose the real, reactive power and voltage control through a transmissi...

متن کامل

STATCOM Analysis for improving Power Quality Constraints - A Literature Survey

With the development and advancement of power electronics devices in recent years, changes in the scenario in the field of controlling and handling the power quality issues have been very effective. FACTS devices are the outstanding approach. In this manuscript,we choose one such FACTS device known as STATCOM, a powerful shunt controller, for discussing its impact and depth how to tackle the po...

متن کامل

H-Bridge Multi Level STATCOM under Different Loads

Voltage control and fast reactive power compensation are two main application area of Static Synchronous Compensator (STATCOM), which is a shunt connected voltage source converter (VSC) based FACTs controller using power semiconductor devices (particularly IGBT, GTO etc.).However, the total Statcom circuitry has complex and coupled system dynamics which require advanced controllers to achieve w...

متن کامل

Flying capacitor multilevel PWM converter based UPFC

A unified power flow controller (UPFC) based on the flying capacitor (FC) multilevel voltage-source converter (VSC) topology with phase-shifted sinusoidal pulse-width modulation (PWM) control is presented. This converter allows higher power handling, potentially lower power loss, lower harmonic distortion and hence less filtering requirements when compared with the typical two-level counterppar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012