Ground-level nitrogen dioxide concentrations inferred from the satellite-borne Ozone Monitoring Instrument

نویسندگان

  • L. N. Lamsal
  • R. V. Martin
  • A. van Donkelaar
  • M. Steinbacher
  • E. A. Celarier
  • E. Bucsela
  • E. J. Dunlea
  • J. P. Pinto
چکیده

[1] We present an approach to infer ground-level nitrogen dioxide (NO2) concentrations by applying local scaling factors from a global three-dimensional model (GEOS-Chem) to tropospheric NO2 columns retrieved from the Ozone Monitoring Instrument (OMI) onboard the Aura satellite. Seasonal mean OMI surface NO2 derived from the standard tropospheric NO2 data product (Version 1.0.5, Collection 3) varies by more than two orders of magnitude (<0.1–>10 ppbv) over North America. Two ground-based data sets are used to validate the surface NO2 estimate and indirectly validate the OMI tropospheric NO2 retrieval: photochemical steady-state (PSS) calculations of NO2 based on in situ NO and O3 measurements, and measurements from a commercial chemiluminescent NO2 analyzer equipped with a molybdenum converter. An interference correction algorithm for the latter is developed using laboratory and field measurements and applied using modeled concentrations of the interfering species. The OMI-derived surface NO2 mixing ratios are compared with an in situ surface NO2 data obtained from the U.S. Environmental Protection Agency’s Air Quality System (AQS) and Environment Canada’s National Air Pollution Surveillance (NAPS) network for 2005 after correcting for the interference in the in situ data. The overall agreement of the OMI-derived surface NO2 with the corrected in situ measurements and PSS-NO2 is 11–36%. A larger difference in winter/spring than in summer/fall implies a seasonal bias in the OMI NO2 retrieval. The correlation between the OMI-derived surface NO2 and the ground-based measurements is significant (correlation coefficient up to 0.86) with a tendency for higher correlations in polluted areas. The satellite-derived data base of ground level NO2 concentrations could be valuable for assessing exposures of humans and vegetation to NO2, supplementing the capabilities of the ground-based networks, and evaluating air quality models and the effectiveness of air quality control strategies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ground-based and Satellite Measurements of Stratospheric Nitrogen Dioxide and Ozone over the South of Portugal

Thanks to the new satellite technology, global scenes of the dynamical and chemical processes of the atmospheric compounds can be drawn. Ground-based equipments have to be used for comparison/validation of the satellite retrievals. The SPATRAM (SPectrometer for Atmospheric TRacers and Aerosol Measurement) is a UV-Vis spectrometer allowing for the measurements of spectral sky radiance along the ...

متن کامل

Effects of local meteorology and aerosols on ozone and nitrogen dioxide retrievals from OMI and pandora spectrometers in Maryland, USA during DISCOVER-AQ 2011

An analysis is presented for both ground- and satellite-based retrievals of total column ozone and nitrogen dioxide levels from the Washington, D.C., and Baltimore, Maryland, metropolitan area during the NASA-sponsored July 2011 campaign of Deriving Information on Surface COnditions from Column and VERtically Resolved Observations Relevant to Air Quality (DISCOVER-AQ). Satellite retrievals of t...

متن کامل

Ground-Level NO2 Concentrations over China Inferred from the Satellite OMI and CMAQ Model Simulations

In the past decades, continuous efforts have been made at a national level to reduce Nitrogen Dioxide (NO2) emissions in the atmosphere over China. However, public concern and related research mostly deal with tropospheric NO2 columns rather than ground-level NO2 concentrations, but actually ground-level NO2 concentrations are more closely related to anthropogenic emissions, and directly affect...

متن کامل

Monitoring of SO2 column concentration over Iran using satellite-based observations during 2005-2016

For the first time, sulfur dioxide concentration was monitored between 2005 and 2016 over Iran which is among the countries with a high SO2 emission rate in the world. To that end, SO2 column concentration at Planetary Boundary Layer (PBL) from Ozone Monitoring Instrument (OMI) was analyzed. OMI is a sensor onboard the Aura satellite which can measure daily SO2 concentration on the global scale...

متن کامل

Ground-based zenith sky abundances and in situ gas cross sections for ozone and nitrogen dioxide with the Earth Observing System Aura Ozone Monitoring Instrument.

High-accuracy spectral-slit-function calibration measurements, in situ ambient absorption gas cell measurements for ozone and nitrogen dioxide, and ground-based zenith sky measurements with the Earth Observing System Aura Ozone Monitoring Instrument (OMI) flight instrument are reported and the results discussed. For use of high-spectral-resolution gas absorption cross sections from the literatu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008