Living history in current orthopaedic hip surgery: intrapelvic teflon granuloma after total hip replacement.
نویسندگان
چکیده
The teflon hip arthroplasty design was used by Sir John Charnley in the early 60's but was taken off the market due to high complication rates. A case is reported of an intrapelvic granuloma after total hip arthroplasty following the use of a teflon socket. This appears to be the last surviving patient treated by Sir John Charnley using a Teflon hip socket design.
منابع مشابه
Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملKnee and Hip Joint Replacement Surgery in a Patient with Ochronotic Arthropathy: Surgical Tips
Ochronosis or black joints disorder is a rare autosomal recessive disorder caused by deficiency of homogentisic acidoxidase. Orthopaedic manifestations are common and mostly involve spine and large joints such as knee and hip.Arthropathy is progressive and will eventually leads to arthroplasty. Not being familiar with this disorder might lead todevastating complications. We present a 57 year-ol...
متن کاملReconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement
Developmental dysplasia of the hip (DDH) or congenital hip dysplasia (CDH) is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DD...
متن کاملTransperitoneal removal of an intrapelvic acetabular component after total hip replacement and salvage of a destroyed acetabulum.
Intrapelvic migration of the acetabular component of a total hip replacement, with severe acetabular destruction making reconstruction impossible, is very rare. We present a patient in whom the component was removed using a laparotomy and a transperitoneal approach with subsequent salvage using a saddle prosthesis and a total femoral replacement.
متن کاملIntrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 76 1 شماره
صفحات -
تاریخ انتشار 2010