Temporal and spatial blood information estimation using Bayesian ICA in dynamic cerebral positron emission tomography

نویسندگان

  • Mika Naganawa
  • Yuichi Kimura
  • Kenji Ishii
  • Keiichi Oda
  • Kiichi Ishiwata
چکیده

Positron emission tomography (PET) is a nuclear medicine technique that provides tomographic images of the distribution of positron-emitting radiopharmaceuticals. We have previously proposed a method for estimating an input blood curve based on a standard independent component analysis using a specially designed cost function and a preprocessing scheme. While the input blood curve was successfully extracted, the voxels with a negative sign remained in the estimated blood volume image. They should be positive because of its physiological meaning. In this study, ensemble learning introduces a nonnegative constraint to correctly estimate temporal and spatial blood information from dynamic cerebral PET images. The rectified Gaussian distribution and exponential distribution were adopted as nonnegative priors on the elements of the time curves and the source images, respectively. The proposed method (extraction of the plasma time-activity curve using ensemble learning, EPEL) was applied to human brain PET studies with three kinds of radiopharmaceuticals for investigating its validity. The results implied that the EPEL-estimated blood curve was similar to the measured curve, and that the estimated blood volume correlated well with that measured clinically. We concluded that EPEL is a valid method for estimating the blood curve and the blood volume image in a noninvasive way. © 2007 Elsevier Inc. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive Extraction of Input Function from Carotid Artery in H2 O Dynamic Brain Positron Emission Tomography Using Independent Component Analysis

For the absolute quantification of regional cerebral blood flow (rCBF) by means of H2 15 O positron emission tomography (PET) and kinetic modeling, arterial input function should be determined accurately. Even if arterial blood sampling, as an input function, provides an accurate time-activity curve (TAC), it is invasive and delay from carotid artery to radial artery should be corrected. Since ...

متن کامل

PET vs. SPECT: in the context of ongoing developments

This paper intends to compare the abilities of the two major imaging modalities in nuclear medicine imaging: Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT). The motivations are many-fold: (i) To gain a better understanding of the strengths and limitations of the two imaging modalities in the context of recent and ongoing developments in hardware ...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Abnormal cerebral blood flow in methamphetamine abusers assessed by brain perfusion single emission computed tomography

Introduction:Amphetamines are central nervous system (CNS) stimulant substances and amphetamine abuse is considered a growing problem in our country. Previous studies revealed destructive effects of amphetamines on metabolism, perfusion and structure of brain. The aim of current study was evaluating regional cerebral blood flow (rCBF) disturbances in methamphetamine (MA) abuser...

متن کامل

A Clinical Application of Ensemble ICA to the Quantification of Myocardial Blood Flow in Dynamic H152 O H^{{15}}_{2} O PET

Ensemble independent component analysis (ICA) is a Bayesian multivariate data analysis method which allows various prior distributions for parameters and latent variables, leading to flexible data fitting. In this paper we apply ensemble ICA with a rectified Gaussian prior to dynamic H 2 O positron emission tomography (PET) image data, emphasizing its clinical usefulness by showing that major c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Digital Signal Processing

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2007