Estimation of synchronous machine parameters by standstill tests
نویسندگان
چکیده
In this paper we present the results of a time-domain identification procedure to estimate the linear parameters of a salient-pole synchronous machine at standstill. A new approach is proposed for the estimation of synchronous machine coupled to DC-chopper and Pseudo Random Binary Sequences excitations; using data recorded during steady-state operation of the chopper-machine unit. This procedure consists of defining and conducting the standstill tests, identifying the model structure, estimating the corresponding parameters, and validating the resulting model. The signals used for identification are the different excitation voltages at standstill and the flowing current in different windings. We estimate the parameters of operational impedances, or in other terms, the reactances and the time constants. The results are presented from tests on a synchronous machine of 3 kVA/220 V/1500 rpm. © 2010 IMACS. Published by Elsevier B.V. All rights reserved.
منابع مشابه
Synchronous Machine Parameter Estimation by Standstill Frequency Response Tests
This paper presents the steps of the approach to identify the linear parameters of a salient-pole synchronous machine at standstill and by frequency response tests data (SSFR). It is currently established and demonstrated that stability parameters for synchronous machines can be obtained by performing frequency response tests with the machine at standstill. The objective of this study is to use...
متن کاملIdentification of Parameters of an A. C. Machine from Standstill Time Domain Data
This paper presents an evaluation of the performance of the maximum likelihood ( M L ) method when used to estimate the linear parameters of a synchronous machine model from the standstill time-domain flux decay test data. It is shown that a unique set of parameters can be obtained and the noise effects can be dealt with effectively when the ML estimation technique is used. The results of study...
متن کاملOnline State Space Model Parameter Estimation in Synchronous Machines
The purpose of this paper is to present a new approach based on the Least Squares Error method for estimating the unknown parameters of the nonlinear 3rd order synchronous generator model. The proposed method uses the mathematical relationships between the machine parameters and on-line input/output measurements to estimate the parameters of the nonlinear state space model. The field voltage is...
متن کاملAn Effective Attack-Resilient Kalman Filter-Based Approach for Dynamic State Estimation of Synchronous Machine
Kalman filtering has been widely considered for dynamic state estimation in smart grids. Despite its unique merits, the Kalman Filter (KF)-based dynamic state estimation can be undesirably influenced by cyber adversarial attacks that can potentially be launched against the communication links in the Cyber-Physical System (CPS). To enhance the security of KF-based state estimation, in this paper...
متن کاملOn the Identification of the Synchronous Machine Parameters Using Standstill DC Decay Test
Usually, the characteristic values of a synchronous machine are obtained from a short-circuit test at no-load. This test requires substantial equipment and is therefore expensive, it implies risks and it can not be always carried out for levels of voltage higher than 50% to 60% of nominal voltage. This DC decay test is an interesting alternative since only light equipment is needed. It delivers...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Mathematics and Computers in Simulation
دوره 81 شماره
صفحات -
تاریخ انتشار 2010