Further biodosimetry investigations using murine partial-body irradiation model.

نویسندگان

  • W F Blakely
  • D J Sandgren
  • V Nagy
  • S-Y Kim
  • G B Sigal
  • N I Ossetrova
چکیده

This study evaluates both the effects of physical restraint and use of candidate biomarkers in a CD2F1 male mouse partial-body irradiation model for biological dosimetry diagnostic assays. Mice were irradiated (6-Gy, 250-kVp X ray) to 3/3rd (total body), 2/3rd (gut and torso), 1/3rd (gut only) and 0/3rd (sham) of total body. Blood was sampled for haematology and blood plasma proteomic biomarkers at 1 and 2 d after exposure. Increases in the body fraction exposed showed progressive decreases in lymphocyte counts and increases in the neutrophil-to-lymphocyte ratios with no significant differences in the neutrophil and platelet counts. The radioresponse for plasma biomarker Flt3L showed proportional increases; however, G-CSF and SAA levels exhibited dramatic and non-proportional increases in levels. Physical restraint at 1 d post-exposure increased lymphocyte counts and SAA, decreased neutrophil-to-lymphocyte ratio and Flt3L and showed no effects on neutrophil and platelet counts or G-CSF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Gamma-H2AX Assay for Radiation Biodosimetry in a Swine Model

There is a paucity of large animal models to study both the extent and the health risk of ionizing radiation exposure in humans. One promising candidate for such a model is the minipig. Here, we evaluate the minipig for its potential in γ-H2AX-based biodosimetry after exposure to ionizing radiation using both Cs137 and Co60 sources. γ-H2AX foci were enumerated in blood lymphocytes and normal fi...

متن کامل

Gene-Expression Biomarkers for Application to High-Throughput Radiation Biodosimetry

Molecular biodosimetry tools are a valuable asset for life-saving medical triage and patient management following a radiological or nuclear disaster. Even with the delayed onset of symptoms, sometimes several days after exposure, gene-expression biomarkers can identify these exposed individuals very early after exposure, allowing for prompt medical intervention. This early assessment of a radia...

متن کامل

Comparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma

Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiatio...

متن کامل

The RABiT: high-throughput technology for assessing global DSB repair.

At the Center for High-Throughput Minimally Invasive Radiation Biodosimetry, we have developed a rapid automated biodosimetry tool (RABiT); this is a completely automated, ultra-high-throughput robotically based biodosimetry workstation designed for use following a large-scale radiological event, to perform radiation biodosimetry measurements based on a fingerstick blood sample. High throughput...

متن کامل

A new Bayesian model for partial body irradiation dose estimation

A new zero–inflated Poisson model is introduced for cytogenetic estimation of partial body radiation dose and fraction of the body irradiated. Bayes factors are also presented to detect if a sample of chromosomal aberrations in blood cells results from partial or whole body irradiation. One example of simulated cytogenetic exposure is shown to demonstrate the usefulness of this methodology in c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 159 1-4  شماره 

صفحات  -

تاریخ انتشار 2014