On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel

نویسندگان

  • Hwon Heo
  • Sungjin Kim
  • Hyeong Hun Lee
  • Hye Rim Cho
  • Wen Jun Xu
  • Se-Hoon Lee
  • Chul-Kee Park
  • Sunghyouk Park
  • Seung Hong Choi
  • Hyeonjin Kim
  • Petras Dzeja
چکیده

Mutations in isocitrate dehydrogenase 1 and 2 (IDH1/2) are frequently found in brain tumors, and the resulting onco-metabolite, 2-hydroxyglutarate (2HG), has been suggested to be a potential diagnostic and prognostic biomarker of the diseases. Indeed, recent studies have demonstrated the feasibility of non-invasively detecting 2HG by using proton magnetic resonance spectroscopy (1H-MRS). Due to severe spectral overlaps of 2HG with its background metabolites and spectral baselines, however, the majority of those previous studies employed spectral editing methods with long echo times (TEs) instead of the most commonly used short TE approach with spectral fitting. Consequently, the results obtained with spectral editing methods may potentially be prone to errors resulting from substantial signal loss due to relaxation. Given that the spectral region where the main signal of 2HG resides is particularly sensitive to spectral baseline in metabolite quantification, we have investigated the impact of incorporating voxel-specifically measured baselines into the spectral basis set on the performance of the conventional short TE approach in 2HG detection in rodent models (Fisher 344 rats; n = 19) of IDH1/2 mutant-overexpressing F98 glioma at 9.4T. Metabolite spectra were acquired (SPECIAL sequence) for a tumor region and the contralateral normal region of the brain for each animal. For the estimation of spectral baselines metabolite-nulled spectra were obtained (double-inversion-recovery SPECIAL sequence) for each individual voxels. Data were post-processed with and without the measured baselines using MRUI and LCModel-the two most widely used data post-processing packages. Our results demonstrate that in-vivo detection of 2HG using the conventional short TE approach is challenging even at 9.4T. However, incorporation of voxel-specifically measured spectral baselines may potentially improve its performance. Upon more thorough validation in a larger number of animals and more importantly in human patients, the potential utility of the proposed short TE acquisition with voxel-specific baseline measurement approach in 2HG detection may need to be considered in the study design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short echo time in vivo prostate ¹H-MRSI.

Visualization of short echo time (TE) metabolites in prostate magnetic resonance spectroscopic imaging is difficult due to lipid contamination and pulse timing constraints. In this work, we present a modified pulse sequence to permit short echo time (TE=40ms) acquisitions with reduced lipid contamination for the detection of short TE metabolites. The modified pulse sequence employs the conforma...

متن کامل

In-Vivo Proton Magnetic Resonance Spectroscopy of 2-Hydroxyglutarate in Isocitrate Dehydrogenase-Mutated Gliomas: A Technical Review for Neuroradiologists

The diagnostic and prognostic potential of an onco-metabolite, 2-hydroxyglutarate (2HG) as a proton magnetic resonance spectroscopy (1H-MRS) detectable biomarker of the isocitrate dehydrogenase (IDH)-mutated (IDH-MT) gliomas has drawn attention of neuroradiologists recently. However, due to severe spectral overlap with background signals, quantification of 2HG can be very challenging. In this t...

متن کامل

Effect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence

Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...

متن کامل

نقش متابولیتها در تشخیص توده های مغزی با استفاده از طیف سنجی تشدید مغناطیس هسته ای و مقایسه غلظت آنها در بیماران تومورال با افراد سالم

Background and Aim: Brain tumors have remained as a significant cause of morbidity and mortality and are often refractory to treatment. The grading of brain tumor has an important implication in clinical management. Currently, magnetic resonance spectroscopy (MRS) is an important dimension in evaluating metabolites and grading brain tumors. The aim of this study is to evaluate metabolites in br...

متن کامل

An in-vivo 1H MRS study of metabolic correlation in IDH1 vs. IDH2 mutated gliomas

Target audience: Neuro-oncologists/-radiologists, and MR spectroscopists in brain tumors. Purpose: A high fraction of gliomas contain mutations in isocitrate dehydrogenases (IDH) 1 and 2 . IDH1 and IDH2 catalyze the NADP dependent conversion of isocitrate to α-ketoglutarate in the cytosol and mitochondria, respectively. The mutations in these enzymes induce a neomorphic enzyme activity, resulti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016