Aerosol delivery during continuous nebulization.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES Continuous administration of aerosolized beta 2-agonists has been suggested as an effective treatment for severe reversible airways disease. To facilitate continuous therapy and avoid a feed system for small-volume nebulizers (SVNs), a large-volume medication nebulizer (Vortran HEART) was developed. The goal of this study was to determine actual drug delivery of the HEART and conventional SVNs for both adult and pediatric breathing patterns. DESIGN Output studies were conducted on comparable samples of CIS-US AeroTech II and Hospitak PowerMist SVNs and Vortran HEART large-volume continuous nebulizers. To duplicate clinical aerosol delivery via an aerosol mask, drug particles were inhaled through the mouth of a model of a human face for two test breathing patterns (adult = tidal volume (Vt) of 500 mL, 20 breaths/min, duty cycle of 40%; pediatric = VT of 100 mL, 35 breaths/min, duty cycle of 40%), generated by a ventilator. Radiolabeled particles of saline solution, confirmed to behave identically to albuterol, were collected on absolute filters at the mouth of the face to measure the actual mass of albuterol particles delivered to the airway opening. RESULTS The AeroTech II and PowerMist SVNs delivered 5.14 and 3.74 mg/h, respectively, for the adult breathing pattern and 2.97 and 2.48 mg/h, respectively, for the pediatric breathing pattern. Drug delivery rates of the HEART were a function of drug concentration and ranged from 0.87 to 3.48 mg/h for the adult breathing pattern. For the pediatric breathing pattern, drug delivery rate was a function of drug concentration and inspired minute ventilation and ranged from 0.41 to 1.83 mg/h. CONCLUSION Our data demonstrate that drug delivery to the patient, expressed as inhaled mass over time, is similar for continuous nebulization (HEART system) and intermittently filled SVNs. In addition, for all nebulizers, the influence of the pediatric breathing pattern needs to be considered. Continuous nebulization permits the redistribution of health-care personnel and may reduce the costs of therapy.
منابع مشابه
Pulmonary Drug Delivery Following Continuous Vibrating Mesh Nebulization and Inspiratory Synchronized Vibrating Mesh Nebulization During Noninvasive Ventilation in Healthy Volunteers.
BACKGROUND A breath-synchronized nebulization option that could potentially improve drug delivery during noninvasive positive pressure ventilation (NIPPV) is currently not available on single-limb circuit bilevel ventilators. The aim of this study was to compare urinary excretion of amikacin following aerosol delivery with a vibrating mesh nebulizer coupled to a single-limb circuit bilevel vent...
متن کاملAerosol delivery and humidification with the Boussignac continuous positive airway pressure device.
BACKGROUND A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. OBJECTIVE To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. METHODS First we a...
متن کاملContinuous nebulization therapy for asthma with aerosols of b2 agonists
Background: Various studies have demonstrated the benefits of continuous nebulization therapy for delivering aerosols of the b2 agonists such as terbutaline sulfate or albuterol sulfate to patients with severe asthma and/or impending respiratory failure. Objective: The purpose of this investigation was to explicate the operational factors associated with the use of nebulizers for extended aeros...
متن کاملContinuous nebulization therapy for asthma with aerosols of beta2 agonists.
BACKGROUND Various studies have demonstrated the benefits of continuous nebulization therapy for delivering aerosols of the beta2 agonists such as terbutaline sulfate or albuterol sulfate to patients with severe asthma and/or impending respiratory failure. OBJECTIVE The purpose of this investigation was to explicate the operational factors associated with the use of nebulizers for extended ae...
متن کاملInfluence of nebulizer type with different pediatric aerosol masks on drug deposition in a model of a spontaneously breathing small child.
BACKGROUND The performance of nebulizers varies with the design type as well as the breathing patterns of various age groups. The present study quantified aerosol delivery using spontaneously breathing parameters of a small child (2-4 years) by a lung simulator to determine the influence of nebulizer type, actuation mechanisms, and pediatric aerosol masks. METHODS Three types of nebulizer (c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 111 5 شماره
صفحات -
تاریخ انتشار 1997