Numerical study of RF exposure and the resulting temperature rise in the foetus during a magnetic resonance procedure.

نویسندگان

  • J W Hand
  • Y Li
  • J V Hajnal
چکیده

Numerical simulations of specific absorption rate (SAR) and temperature changes in a 26-week pregnant woman model within typical birdcage body coils as used in 1.5 T and 3 T MRI scanners are described. Spatial distributions of SAR and the resulting spatial and temporal changes in temperature are determined using a finite difference time domain method and a finite difference bio-heat transfer solver that accounts for discrete vessels. Heat transfer from foetus to placenta via the umbilical vein and arteries as well as that across the foetal skin/amniotic fluid/uterine wall boundaries is modelled. Results suggest that for procedures compliant with IEC normal mode conditions (maternal whole-body averaged SAR(MWB) < or = 2 W kg(-1) (continuous or time-averaged over 6 min)), whole foetal SAR, local foetal SAR(10 g) and average foetal temperature are within international safety limits. For continuous RF exposure at SAR(MWB) = 2 W kg(-1) over periods of 7.5 min or longer, a maximum local foetal temperature >38 degrees C may occur. However, assessment of the risk posed by such maximum temperatures predicted in a static model is difficult because of frequent foetal movement. Results also confirm that when SAR(MWB) = 2 W kg(-1), some local SAR(10g) values in the mother's trunk and extremities exceed recommended limits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synergistic effects of Radiofrequency Hyperthermia temperature rate with magnetic Graphene oxide nanoparticles drug targeting on CT26 colon cancer cell line

Introduction: Graphene oxide (GO) sheets are carbon-networking nanomaterials offering excellent potential for drug delivery platforms due to hydrophobic interactions and high drug-loading efficiency. Superparamagnetic iron oxide nanoparticles can be used in certain applications such as cell labeling, drug delivery, targeting, magnetic resonance imaging and hyperthermia. Due t...

متن کامل

CYTOGENETIC EFFECTS OF MAGNETIC AND RADIOFREQUENCY FIEL DS OF NMRI SYSTEMS ON THE FREQUENCY OF CHROMOSOMAL ABERRATIONS INHUMAN LYMPHOCYTES IN THE PRESENCE OR ABSENCE OF CYTOSINE ARABINOSIDE

Application of nuclear magnetic resonance imaging (NMRI) as a non-invasive and accurate imaging procedure has been widely used in recent years. Meanwhile, the biological effects of magnetic fields of several tesla (T) and high energy radiofrequency (RF) is not fully known yet. Because of controversy over this issue, the present research has been carried out in order to verify the effects of...

متن کامل

“Triple M” Effect: A Proposed Mechanism to Explain Increased Dental Amalgam Microleakage after Exposure to Radiofrequency Electromagnetic Radiation

A large body of evidence now indicates that the amount of mercury released from dental amalgam fillings can be significantly accelerated by exposure to radiofrequency electromagnetic fields (RF-EMFs) such as common mobile phones and magnetic resonance imaging (MRI). Studies performed on the increased microleakage of dental amalgam restorations after exposure to RF-EMFs have further supported th...

متن کامل

Relationship between the Exposure to Magnetic Fields during Pregnancy and Risk of Abortion: A Review Article

Background Exposure to electro-magnetic fields is a risk factor for abortion. We aimed to review the relationship between exposure to magnetic fields during pregnancy and the risk of abortion. Materials and Methods: Two independent researchers screened the articles with related keywords including: "Radiofrequency", "RF", "RF-EMFs",...

متن کامل

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2010