Effect of phosphate group addition on the properties of denture base resins.

نویسندگان

  • Gaurav Puri
  • David W Berzins
  • Virendra B Dhuru
  • Periathamby A Raj
  • Sameer K Rambhia
  • Gunjan Dhir
  • Andrew R Dentino
چکیده

STATEMENT OF PROBLEM Acrylic resins are prone to microbial adherence, especially by Candida albicans. Surface-charged resins alter the ionic interaction between the denture resin and Candida hyphae, and these resins are being developed as a means to reduce microbial colonization on the denture surface. PURPOSE The purpose of this study was to investigate the physical and mechanical properties of phosphate-containing polymethyl methacrylate resins for their suitability as a denture material. MATERIAL AND METHODS Using PMMA with cross-linker (Lucitone 199) as a control, 4 experimental groups containing various levels of phosphate with and without cross-linker were generated. The properties examined were impact strength, fracture toughness, wettability (contact angle), and resin bonding ability to denture teeth. Impact strength was tested in the Izod configuration (n=16), and fracture toughness (n=13) was measured using the single-edge notched bend test. Wettability was determined by calculating the contact angle of water on the material surface (n=12), while ISO 1567 was used for bonding ability (n=12). The data were analyzed by 1- and 2-way ANOVA (alpha=.05). RESULTS A trend of increased hydrophilicity, as indicated by lower contact angle, was observed with increased concentrations of phosphate. With regard to the other properties, no significant differences were found when compared with the control acrylic resin. CONCLUSIONS No adverse physical effect due to the addition of a phosphate-containing monomer was found in the acrylic denture resins. Additional mechanical and physical properties, biocompatibility, and clinical efficacy studies are needed to confirm the in vivo anti-Candida activity of these novel resins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Addition of Silver Nanoparticles to Denture Base Resin Increase Its Thermal Conductivity?

  Objective: Studies have demonstrates that physical properties of denture base affect patient satisfaction and acceptance. Thermal conductivity is among the most important properties of denture base influencing the sense of taste and gingival health. The conventionally used acrylic resin has a low coefficient of thermal conductivity. This study aimed to improve the thermal conductivity of acry...

متن کامل

Determination of Residual Methylmethacrylate Monomerin Denture Base Resins by Gas Chromatography

Acrylic base resins are widely used in orthopedics and dental surgery. It is generally accepted that due to the incomplete conversion of methyl methacrylate (MMA) monomer to the polymer form during polymerization of the resin, some MMA monomers remain in the hardened material. MMA monomer has been reported to cause abnormalities or lesions in several organs of animals. Study of the literatures ...

متن کامل

Flexural properties and impact strength of denture base resins reinforced with micronized glass flakes

OBJECTIVES To investigate the effect of the addition of glass flakes on physical properties of conventional heat cure denture base resins and to compare it with a high impact strength denture base resin. MATERIALS AND METHODS Test specimens were divided into Group 1 - poly (methyl methacrylate) (PMMA) (Trevalon), Group 2 - Trevalon HI, Group 3 -5% glass flake +95% PMMA (Trevalon), Group 4 -10...

متن کامل

Silver nanoparticle incorporation effect on mechanical and thermal properties of denture base acrylic resins

Objective The aim of the present study was to evaluate the mechanical and thermal characteristics of two denture base acrylic resins containing silver nanoparticles (AgNPs). Material and Methods Two different acrylic denture base resins (heat-polymerized and microwave polymerized) containing 0.3, 0.8 and 1.6 wt% AgNPs were evaluated for flexural strength, elastic modulus and impact strength. ...

متن کامل

Determination of Residual Methylmethacrylate Monomerin Denture Base Resins by Gas Chromatography

Acrylic base resins are widely used in orthopedics and dental surgery. It is generally accepted that due to the incomplete conversion of methyl methacrylate (MMA) monomer to the polymer form during polymerization of the resin, some MMA monomers remain in the hardened material. MMA monomer has been reported to cause abnormalities or lesions in several organs of animals. Study of the literatures ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 100 4  شماره 

صفحات  -

تاریخ انتشار 2008