Automated registration of dynamic contrast enhanced DCE-MRI cardiac perfusion achieves comparable diagnostic accuracy to manual motion correction: a CE-MARC sub-study
نویسندگان
چکیده
Background The human interaction required for manual motion correction/contouring of cardiac perfusion series remains a significant obstacle to quantitative perfusion gaining a wider acceptance in clinical practice. The use of image registration for motion correction in perfusion data offers a considerable time saving. Numerous registration methods have been proposed, with evaluation limited to the image registration accuracy. However, the important clinical question is how do these methods affect diagnosis? The aim of this study is to evaluate perfusion series registration in terms of its affect on the diagnostic accuracy of myocardial ischaemia.
منابع مشابه
A comparison of methods for automated motion correction of DCE-MRI perfusion datasets evaluated in terms of diagnostic accuracy: a CE-MARC sub-study
Background Automated mage registration in cardiac myocardial perfusion is a necessity before quantitative perfusion can be widely accepted in clinical practice. Increasingly complex motion correction algorithms are being developed to deal with cardiac motion. However, the impact of these improvements has not been evaluated in terms of the final clinical diagnosis. Advanced motion correction met...
متن کاملAutomatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...
متن کاملModel-based registration for dynamic cardiac perfusion MRI.
PURPOSE To assess the accuracy of a model-based approach for registration of myocardial dynamic contrast-enhanced (DCE)-MRI corrupted by respiratory motion. MATERIALS AND METHODS Ten patients were scanned for myocardial perfusion on 3T or 1.5T scanners, and short- and long-axis slices were acquired. Interframe registration was done using an iterative model-based method in conjunction with a m...
متن کاملIs the rest perfusion measurement necessary for the diagnosis of myocardial ischaemia in quantitative cardiac perfusion? A CE-MARC sub-study
Background Diagnostic studies using dynamic contrast enhanced (DCE) MRI perfusion imaging typically evaluate perfusion in terms of the myocardial perfusion reserve (MPR), which is the ratio of stress to rest myocardial blood flow (MBF) measurements. The aim of this study was to establish whether or not, in the case of absolute MBF quantitation, the MPR exhibits a diagnostic advantage over the s...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کامل