Dependency of magnetocardiographically determined fetal cardiac time intervals on gestational age, gender and postnatal biometrics in healthy pregnancies
نویسندگان
چکیده
BACKGROUND: Magnetocardiography enables the precise determination of fetal cardiac time intervals (CTI) as early as the second trimester of pregnancy. It has been shown that fetal CTI change in course of gestation. The aim of this work was to investigate the dependency of fetal CTI on gestational age, gender and postnatal biometric data in a substantial sample of subjects during normal pregnancy. METHODS: A total of 230 fetal magnetocardiograms were obtained in 47 healthy fetuses between the 15th and 42nd week of gestation. In each recording, after subtraction of the maternal cardiac artifact and the identification of fetal beats, fetal PQRST courses were signal averaged. On the basis of therein detected wave onsets and ends, the following CTI were determined: P wave, PR interval, PQ interval, QRS complex, ST segment, T wave, QT and QTc interval. Using regression analysis, the dependency of the CTI were examined with respect to gestational age, gender and postnatal biometric data. RESULTS: Atrioventricular conduction and ventricular depolarization times could be determined dependably whereas the T wave was often difficult to detect. Linear and nonlinear regression analysis established strong dependency on age for the P wave and QRS complex (r2 = 0.67, p < 0.001 and r2 = 0.66, p < 0.001) as well as an identifiable trend for the PR and PQ intervals (r2 = 0.21, p < 0.001 and r2 = 0.13, p < 0.001). Gender differences were found only for the QRS complex from the 31st week onward (p < 0.05). The influence on the P wave or QRS complex of biometric data, collected in a subgroup in whom recordings were available within 1 week of birth, did not display statistical significance. CONCLUSION: We conclude that 1) from approximately the 18th week to term, fetal CTI which quantify depolarization times can be reliably determined using magnetocardiography, 2) the P wave and QRS complex duration show a high dependency on age which to a large part reflects fetal growth and 3) fetal gender plays a role in QRS complex duration in the third trimester. Fetal development is thus in part reflected in the CTI and may be useful in the identification of intrauterine growth retardation.
منابع مشابه
Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies
BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...
متن کاملP-179: The Role of Fetal Sex on Preterm Labor
Background: Preterm labor is a major problem in obstetric practice. Rates of preterm birth vary between different populations and ethnic groups. In maternal fetal medicine, gender differences in outcome are often observed. Epidemiologic studies have suggested that the incidence of preterm birth is also higher in pregnancies carrying a male fetus. The purpose of this article is to review the evi...
متن کاملInm-3: Reduction: Reasons and Consequences
During the recent decades with increasing the use of assisted reproductive techniques including IVF, IUI and ovulation induction, the rate of multiple pregnancies has been increased worldwide. More than 30% of ART pregnancies are twins or higher-order multiple gestations (triplets or greater) a frequency 15- to 20-fold greater than with spontaneous conceptions. Because of the high cost of treat...
متن کاملFetal pulmonary venous flow into the left atrium relative to diastolic and systolic cardiac time intervals.
OBJECTIVE To establish the nature and gestational age dependency of the pulmonary venous flow velocity pattern into the left atrium relative to systolic and diastolic phases of the cardiac cycle. DESIGN This was a cross-sectional study of Doppler measurements of fetal pulmonary venous inflow velocities, which were correlated with simultaneous recordings of transmitral and aortic flow velocity...
متن کاملUltrasound evaluation of fetal gender at 12-14 weeks.
AIMS The aim of this study was to assess the feasibility and accuracy of fetal gender assignment by transabdominal ultrasound at 12-14 weeks of gestation. METHODS Fetal gender assessment was performed in 1222 singleton pregnancies. In all fetuses the crown-rump length (CRL) was measured and the genital area of the fetus was examined in the mid-sagittal plane. The result of ultrasound examinat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC Pregnancy and Childbirth
دوره 4 شماره
صفحات -
تاریخ انتشار 2004