Deactivation force-deflection behavior of multistranded stainless steel wires.

نویسندگان

  • Parul Taneja
  • Manville G Duncanson
  • Sharukh S Khajotia
  • Ram S Nanda
چکیده

This investigation measured the deactivation (unloading) force-deflection behavior of selected multistranded stainless steel orthodontic wires. The guidelines from the revised American National Standards Institute/American Dental Association Specification No. 32 for orthodontic wires (type 2, nonlinear elasticity) were used to perform a 3-point bending test to obtain data for the deactivation force levels at 3, 2, 1, and 0.5 mm, and permanent deformation values. The study tested 20 wire designs: triple-stranded twisted wires, 5- and 6-stranded coaxial wires, and 8- and 9-stranded braided rectangular wires of selected cross-sections. Twenty specimens were tested for each wire design. The specification guidelines for testing provided a means for obtaining comparative unloading force delivery data for the deflections tested. Multistranded wires of significantly different cross-section, weave, and strand number fell within relatively narrow ranges of force delivery at the 0.5-mm (1.7-42.7 grams-force [gmf]) and 1-mm (31.1-134.2 gmf) deflections and wider ranges of force levels at the 2-mm (57.0-320.5 gmf) and 3-mm (72.5-451.8 gmf) deflections. All wires exhibited some permanent deformation, but none averaged greater than 0.66 mm. The testing also showed that multistranded wires of significantly different design exhibit similar force levels. The guidelines of the revised Specification No. 32 yielded deactivation data with regard to force delivery and provided comparisons of the wire designs tested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Force-deflection properties of initial orthodontic archwires.

AIM This in vitro study measured the force-deflection behavior of selected initial alignment archwires by conducting three-point bending tests under controlled conditions. The study tested four wire designs: multistranded stainless steel, conventional stainless steel, superelastic nickel-titanium, and thermoactivated nickel-titanium archwires. METHOD The wires (n = 15) were ligated into stain...

متن کامل

Mechanical evaluation of space closure loops in orthodontics.

This study evaluated the mechanical performance of teardrop-shaped loops and teardrop-shaped loops with helix used in orthodontic space closure. Sixty retraction loops made with 0.019" x 0.025" stainless steel (SS) and beta-titanium (BT) wires were used. They were attached to a testing machine to measure the magnitudes of the sagittal force and the load-deflection ratio necessary for 1 mm, 2 mm...

متن کامل

Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were asse...

متن کامل

A randomized clinical trial investigating pain associated with superelastic nickel–titanium and multistranded stainless steel archwires during the initial leveling and aligning phase of orthodontic treatment

OBJECTIVE To investigate and compare the effects of superelastic nickel-titanium and multistranded stainless steel archwires on pain during the initial phase of orthodontic treatment. DESIGN A double-blind two-arm parallel design stratified randomized clinical trial. SETTING A single centre in India between December 2010 and June 2012. A total of 96 participants (48 male and 48 females; 14....

متن کامل

Evaluation of deflection forces of orthodontic wires with different ligation types.

The aim of this study was to evaluate deflection forces of orthodontic wires of different alloys engaged into conventional brackets using several ligation types. Stainless steel, conventional superelastic nickel-titanium and thermally activated nickel-titanium archwires tied into conventional brackets by a ring-shaped elastomeric ligature (RSEL), a 8-shaped elastomeric ligature (8SEL) and a met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics

دوره 124 1  شماره 

صفحات  -

تاریخ انتشار 2003