High variability in strain estimation errors when using a commercial ultrasound speckle tracking algorithm on tendon tissue.
نویسندگان
چکیده
BACKGROUND Ultrasound speckle tracking offers a non-invasive way of studying strain in the free Achilles tendon where no anatomical landmarks are available for tracking. This provides new possibilities for studying injury mechanisms during sport activity and the effects of shoes, orthotic devices, and rehabilitation protocols on tendon biomechanics. PURPOSE To investigate the feasibility of using a commercial ultrasound speckle tracking algorithm for assessing strain in tendon tissue. MATERIAL AND METHODS A polyvinyl alcohol (PVA) phantom, three porcine tendons, and a human Achilles tendon were mounted in a materials testing machine and loaded to 4% peak strain. Ultrasound long-axis cine-loops of the samples were recorded. Speckle tracking analysis of axial strain was performed using a commercial speckle tracking software. Estimated strain was then compared to reference strain known from the materials testing machine. Two frame rates and two region of interest (ROI) sizes were evaluated. RESULTS Best agreement between estimated strain and reference strain was found in the PVA phantom (absolute error in peak strain: 0.21 ± 0.08%). The absolute error in peak strain varied between 0.72 ± 0.65% and 10.64 ± 3.40% in the different tendon samples. Strain determined with a frame rate of 39.4 Hz had lower errors than 78.6 Hz as was the case with a 22 mm compared to an 11 mm ROI. CONCLUSION Errors in peak strain estimation showed high variability between tendon samples and were large in relation to strain levels previously described in the Achilles tendon.
منابع مشابه
Temperature Mapping Using Ultrasound Digital Images
Introduction: The success of hyperthermia depends on the accuracy of the temperature monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes were determined by computing the speckle displacement in the ultrasound digital images. Speckle tracking algorithm was used to compute the displacement. Materials and Methods: The experiment was perf...
متن کاملComputer Vision Elastography
This thesis is concerned with developing a two-dimensional (2D) ultrasound speckle tracking technique to quantify 2D axial and lateral strain fields for studying tissue dynamics. Knowledge of tissue displacement to infer strain characteristics is of major clinical importance. In part, this is due to the lack of simple and accurate non-invasive techniques to measure in vivo strain. The establish...
متن کاملSpeckle tracking ultrasound for assessment of the relative motion of flexor tendon and subsynovial connective tissue in the human carpal tunnel.
The objective of this study was to compare tissue Doppler imaging and speckle tracking ultrasound to assess the relative motion of flexor tendon and surrounding subsynovial connective tissue (SSCT). Twenty normal human wrists were imaged with an ultrasound scanner. The two ultrasound methods measured the excursion and maximum velocity of the tendon and SSCT while subjects gripped three differen...
متن کاملStrain assessment in the carotid artery wall using ultrasound speckle tracking: validation in a sheep model.
The aim of this study was to validate carotid artery strain assessment in-vivo using ultrasound speckle tracking. The left carotid artery of five sheep was exposed and sonomicrometry crystals were sutured onto the artery wall to obtain reference strain. Ultrasound imaging was performed at baseline and stress, followed by strain estimation using an in-house speckle tracking algorithm tuned for v...
متن کاملEvaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)
The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta radiologica
دوره 57 10 شماره
صفحات -
تاریخ انتشار 2016