Reproducibility of quantitative CT brain perfusion measurements in patients with symptomatic unilateral carotid artery stenosis.
نویسندگان
چکیده
BACKGROUND AND PURPOSE To establish intraobserver and interobserver variability for regional measurement of CT brain perfusion (CTP) and to determine whether reproducibility can be improved by calculating perfusion ratios. MATERIALS AND METHODS CTP images were acquired in 20 patients with unilateral symptomatic carotid artery stenosis (CAS). We manually drew regions of interest (ROIs) in the cortical flow territories of the anterior (ACA), middle (MCA), and posterior (PCA) cerebral arteries and the basal ganglia in each hemisphere; recorded cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT); and calculated ratios of perfusion values between symptomatic and asymptomatic hemisphere. We assessed intraobserver and interobserver variability by performing a Bland-Altman analysis of the relative differences between 2 observations and calculated SDs of relative differences (SDD(rel)) as a measure of reproducibility. We used an F test to assess significance of differences between SDD(rel) of absolute CTP values and CTP ratios, and the Levine test to compare the 4 perfusion territories. RESULTS MTT was the most reproducible parameter (SDD(rel) <or= 10%). Intraobserver and interobserver variability were higher for absolute CTP values compared with CTP ratios for CBV (16%-17% versus 11%-16%) and CBF (18% versus 10%-13%) but not for MTT (5%-9%). Reproducibility was best in the MCA territory: SDD(rel) was <or=11% for perfusion ratios of all 3 parameters. CONCLUSION MTT is the most reproducible CTP parameter in patients with unilateral symptomatic CAS. Measurement variability in CBV and CBF can be improved if CTP ratios instead of CTP values are used. The MCA territory shows the least measurement variability.
منابع مشابه
Sixty-four-section CT cerebral perfusion evaluation in patients with carotid artery stenosis before and after stenting with a cerebral protection device.
BACKGROUND AND PURPOSE Brain tissue viability depends on cerebral blood flow (CBF) that has to be kept within a narrow range to avoid the risk of developing ischemia. The aim of the study was to evaluate by 64-section CT (VCT) the cerebral perfusion modifications in patients with severe carotid stenosis before and after undergoing carotid artery stent placement (CAS) with a cerebral protection ...
متن کاملHemodynamic segmentation of MR perfusion images in patients with unilateral carotid stenosis using independent component analysis.
PURPOSE To assess spatiotemporal patterns of local perfusion in MR brain perfusion images for patients with unilateral carotid stenosis. MATERIALS AND METHODS MR perfusion images acquired from 12 patients with unilateral carotid stenosis were retrospectively segmented using independent component analysis. Regions of interest selected from the segmentation results were used to measure the time...
متن کاملHemodynamic modifications in patients with symptomatic unilateral stenosis of the internal carotid artery: evaluation with MR imaging perfusion sequences.
BACKGROUND AND PURPOSE Risk of developing ischemia is higher in patients with reduced cerebrovascular reactivity than in those with preserved cerebrovascular reactivity. Therefore, we assessed cerebral hemodynamic modifications in patients with unilateral stenosis of the internal carotid artery by using perfusion-weighted MR imaging to determine if these modifications underlie or anticipate isc...
متن کاملANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملUsing Flat-Panel Perfusion Imaging to Measure Cerebral Hemodynamics
Flat-detector CT perfusion (FD-CTP) imaging has demonstrated efficacy in qualitatively accessing the penumbra in acute stroke equivalent to that of magnetic resonance perfusion (MRP). The aim of our study was to evaluate the feasibility of quantifying oligemia in the brain in patients with carotid stenosis.Ten patients with unilateral carotid stenosis of >70% were included. All MRPs and FD-CTPs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2007