Rapid-acquisition myocardial perfusion scintigraphy (MPS) on a novel gamma camera using multipinhole collimation and miniaturized cadmium-zinc-telluride (CZT) detectors: prognostic value and diagnostic accuracy in a 'real-world' nuclear cardiology service.
نویسندگان
چکیده
AIMS To study the prognostic value of rapid-acquisition adenosine stress-rest myocardial perfusion scintigraphy (MPS) on a gamma camera using multipinhole collimation and cadmium-zinc-telluride (CZT) detectors. The secondary aim was to assess the diagnostic accuracy of the technique compared with invasive coronary angiography. METHODS AND RESULTS Retrospective analysis of 1109 consecutive patients undergoing MPS in a routine clinical setting on a high-efficiency multipinhole gamma camera. MPS acquisition, performed with a standard injection of 550 MBq of (99m)Tc-tetrofosmin, required a mean (±SD) scanning time of 322 ± 51 s. The hard cardiac event rate at a median (inter-quartile range) follow-up of 624 (552-699) days was 0.4% (95% CI 0.1-1.1) in patients with no significant perfusion abnormality versus 6.8% (95% CI 4.3-10.7%, P < 0.001) in those with an abnormal scan. In a sub-group of 165 patients, comparison with obstructive coronary artery disease on X-ray angiography gave a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for rapid-acquisition MPS of 84% (95% CI 74-91), 79% (95% CI 68-87), 82% (95% CI 72-89), 81% (95% CI 70-89), and 82% (95% CI 73-89), respectively. CONCLUSIONS MPS performed on a CZT solid-state detector camera with multipinhole collimation is an evolutionary development that provides reliable prognostic and diagnostic information, while significantly reducing image acquisition time.
منابع مشابه
99mTc-MDP bone scintigraphy of the hand: comparing the use of novel cadmium zinc telluride (CZT) and routine NaI(Tl) detectors
BACKGROUND Cadmium zinc telluride (CZT) solid-state detectors have been recently introduced in the field of nuclear medicine in cardiology and breast imaging. The aim of the current study was to evaluate the performance of the novel detectors (CZT) compared to that of the routine NaI(Tl) in bone scintigraphy. A dual-headed CZT-based camera dedicated originally to breast imaging has been used, a...
متن کاملReduced administered activity, reduced acquisition time, and preserved image quality for the new CZT camera.
BACKGROUND For a 1-day myocardial perfusion SPECT (MPS) the recommendations for administered activity stated in the EANM guidelines results in an effective dose of up to 16 mSv per patient. Recently, a gamma camera system, based on cadmium zinc telluride (CZT) technology, was introduced. This technique has the potential to reduce the effective dose and scan time compared to the conventional NaI...
متن کاملNuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction.
UNLABELLED We aimed at establishing the optimal scan time for nuclear myocardial perfusion imaging (MPI) on an ultrafast cardiac gamma-camera using a novel cadmium-zinc-telluride (CZT) solid-state detector technology. METHODS Twenty patients (17 male; BMI range, 21.7-35.5 kg/m(2)) underwent 1-d (99m)Tc-tetrofosmin adenosine stress and rest MPI protocols, each with a 15-min acquisition on a st...
متن کاملAbsolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium-Zinc-Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET.
Recent advances in SPECT technology including cadmium-zinc-telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K1 uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. METHODS A...
متن کاملValue of automatic patient motion detection and correction in myocardial perfusion imaging using a CZT-based SPECT camera
BACKGROUND Correction of motion has become feasible on cadmium-zinc-telluride (CZT)-based SPECT cameras during myocardial perfusion imaging (MPI). Our aim was to quantify the motion and to determine the value of automatic correction using commercially available software. METHODS AND RESULTS We retrospectively included 83 consecutive patients who underwent stress-rest MPI CZT-SPECT and invasiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2014