Increased risk of aseptic loosening for 43,525 rotating-platform vs. fixed-bearing total knee replacements
نویسندگان
چکیده
Background and purpose - Given similar functional outcomes with mobile and fixed bearings, a difference in survivorship may favor either. This study investigated the risk of aseptic loosening for the most used subtypes of mobile-bearing rotating-platform knees, in Norway and Australia. Patients and methods - Primary TKRs reported to the Norwegian and Australian joint registries, between 2003 and 2014, were analyzed with aseptic loosening as primary end-point and all revisions as secondary end-point. We hypothesized that no difference would be found in the rate of revision between rotating-platform and the most used fixed-bearing TKRs, or between keeled and non-keeled tibia. Kaplan-Meier estimates and curves, and Cox regression relative risk estimates adjusted for age, sex, and diagnosis were used for comparison. Results - The rotating-platform TKRs had an increased risk of revision for aseptic loosening compared with the most used fixed-bearing knees, in Norway (RR =6, 95% CI 4-8) and Australia (RR =2.1, 95% CI 1.8-2.5). The risk of aseptic loosening as a reason for revision was highest in Norway compared with Australia (RR =1.7, 95% CI 1.4-2.0). The keeled tibial component had the same risk of aseptic loosening as the non-keeled tibia (Australia). Fixation method and subtypes of the tibial components had no impact on the risk of aseptic loosening in these mobile-bearing knees. Interpretation - The rotating-platform TKRs in this study appeared to have a higher risk of revision for aseptic loosening than the most used fixed-bearing TKRs.
منابع مشابه
High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement.
We have examined the results obtained with 72 NexGen legacy posterior stabilised-flex fixed total knee replacements in 47 patients implanted by a single surgeon between March 2003 and September 2004. Aseptic loosening of the femoral component was found in 27 (38%) of the replacements at a mean follow-up of 32 months (30 to 48) and 15 knees (21%) required revision at a mean of 23 months (11 to 4...
متن کاملComparison of Wear in Fixed and Mobile Bearing Knee Designs
Ultra High Molecular Weight Polyethylene (UHMWPE) remains the only bearing surface of choice in total knee replacements (TKR). While excellent medium term results can be found for knee replacements at ten years, there remains concerns about wear debris induced osteolysis in the longer term, particularly in young and more active patients. It has been shown previously that the wear of fixed beari...
متن کاملRotating-hinge total knee for revision total knee arthroplasty.
Rotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.8 years. Indications for surgery were aseptic loosening...
متن کاملComparative gravimetric wear analysis in mobile versus fixed-bearing posterior stabilized total knee prostheses.
Polyethylene (PE) wear is the limiting factor for the longevity of a conventional total knee arthroplasty (TKA). Excessive wear leads to loosening and eventual implant failure. The aim of our in vitro study was to investigate wear of a PE tibial insert on a rotating platform as compared to the same insert fixed to the tibial baseplate and articulating with a similar femoral component. All tests...
متن کاملBilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing.
We compared the early results of mobile-bearing knee prosthesis with fixed-bearing knee prosthesis in 16 patients who had one-stage, sequential, bilateral replacements. In each patient, a Low Contact Stress (LCS, Depuy) rotating-platform prosthesis was inserted in one side, and an Anatomic Modular Knee (AMK, Depuy) posterior-stabilised prosthesis was inserted in the other side. The same surgica...