Characterization and radiation testing of the Harris HS9008RH flash analogue to digital converter

نویسندگان

  • H. B. Crawley
  • S. Nutter
چکیده

Results from tests characterizing the performance and radiation hardness of the HS9008RH flash analog to digital convertor (FADC) are presented. These tests were performed primarily to evaluate the suitability of this device for use 1n the GEM Central Tracker at the SSC experiment . Basic performance characteristics and susceptibility of these characteristics to radiation were examined . Performance test results indicate that the device integral nonlinearity is sampling rate dependent and worsens rapidly above a sampling rate of 15 megasamples per second (MSPS). No degradation in performance of the device was observed after its exposure of up to 81 Mrad of 1.25 MeV y radiation from a 60Co source . Exposure of the device to a reactor fast neutron fluence (E > 100 keV) of 5 x 10 14/cm2 resulted in no significant observed performance degradation as well .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AVR120: Characterization and Calibration of the ADC on an AVR

This application note explains various ADC (Analog to Digital Converter) characterization parameters given in the datasheets and how they effect ADC measurements. It also describes how to measure these parameters during application testing in production and how to perform run-time compensation for some of the measured deviations. A great advantage with the Flash memory of the Atmel AVR is that ...

متن کامل

Transition from analogue-to-digital nuclear electronics for precise gamma radiation spectroscopy: advantages and limitations

In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...

متن کامل

Review of Flash Analogue to Digital Converter

This research presents the review of Analog to Digital Convertor (ADC). For ADC there are mainly four different methods, Flash ADC, Pipelined ADC, Successive Approximation ADC, and Sigma Delta ADC. The Flash ADC is the Fast ADC. For Designing the ADC, the parameters important are Static and Dynamic. In static parameters Differential Non Linearity Error (DNLE), Integral Non Linearity Error (INLE...

متن کامل

Characterization and production testing of a quad 12 bit 40 Ms/sec A/D converter with automatic digital range selection for calorimetry

The AD41240 is a custom made 12-bit 40 MSPS, quadchannel, radiation tolerant analog-to-digital converter for the front-end readout electronics of the CMS Electromagnetic Calorimeter (ECAL) and the CMS Preshower detectors. The A/D converter features a special digital circuitry to allow automatic selection of gain ranges when it is used with a multi gain pre-amplifier. This paper describes the de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002