Umbilical cord blood gas analysis at delivery: a time for quality data.

نویسندگان

  • J Westgate
  • J M Garibaldi
  • K R Greene
چکیده

OBJECTIVES To address the practical problems of routine umbilical cord blood sampling, to determine the ranges for pH, PCO2 and base deficit and to examine the relationships of these parameters between cord vessels. DESIGN An observational study of umbilical cord artery and vein blood gas results. SETTING A large district general hospital in the UK. SUBJECTS One thousand nine hundred and forty-two cord results from 2013 consecutive pregnancies of 34 weeks or more gestation, monitored by fetal scalp electrode during labour. RESULTS Only 1448 (74.6%) of the 1942 supposedly paired samples had validated pH and PCO2 data both from an artery and the vein; 54 (2.8%) had only one blood sample available, 90 (4.6%) had an error in the pH or PCO2 of one vessel and in 350 (18%) pairs the differences between vessels indicated that they were not sampled from artery and vein as intended. Only 60% of the cases with an arterial pH less than 7.05 had evidence of a metabolic acidosis (base deficit in the extracellular fluid 10 mmol/l or more). Of all the cases, 2.5% had a venous-arterial pH difference greater than 0.22 units. CONCLUSIONS Both artery and vein cord samples must be taken and the results screened to ensure separate vessels have been sampled. Interpretation of the results requires the examination of PCO2 and base deficit of the extracellular fluid from each vessel as well as the pH. Confusion about the value of cord gas measurements may be due to the use of erroneous data and inadequate definitions of acidosis which do not differentiate between respiratory and metabolic components.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Correlation between Type of Delivery and Umbilical Cord Blood Hemoglobin and Hematocrit in Full- Term Neonates

Introduction: Neonates with lower hemoglobin and Hematocrit are more at risk of iron deficiency anemia. This rate is influenced by several factors. Children's health can be improved by identifying these factors and taking appropriate actions. This study determined the relationship between type of delivery and umbilical cord blood hemoglobin and Hematocrit. Methods: This descriptive correlation...

متن کامل

The Effect of mode of delivery on the umbilical artery pH

Background: Abnormal umbilical cord pH can be indicated a distress imposed of newborn and can also be useful in determining the prognosis of the newborn. There are different views about the effect of the neonatal delivery method on the blood gas analysis of the umbilical artery. This study aimed to determine the effect of the method of delivery on umbilical artery pH. Methods: In this Cross ...

متن کامل

Umbilical Cord Arterial Blood Gas and Apgar Score: Who Is at Higher Risk?

Background: Fetal asphyxia and the consequent neurological damages could be avoided if the risk factors are controlled at earlier stages. Umbilical cord arterial blood gas (UCABG) seems to be related to the Apgar scores, as well as the neonatal morbidity and mortality rates. Therefore, we designed this study to assess the correlation between the Apgar score and UCABG i...

متن کامل

بررسی تأثیر تجویز اکسیژن به مادر در مرحله دوم زایمان بر روی گازهای خون بند ناف

This study was conducted to assess the role of maternal oxygen    administration during the second stage of labor on umbilical cord blood gas    values.  This study was done in Fatemieh hospital on 160 pregnant women    who were admitted for vaginal delivery and had the inclusion criteria.           A group ...

متن کامل

مقایسه گازهای خون بندناف واپگار نوزادان حاصل از زایمان طبیعی و سزارین به روش بیهوشی عمومی وبی حسی نخاعی

Background: Umbilical cord blood gas analysis is a useful method for assessment of oxygenation and acid-base status in neonates. Severe fetal acidemia is associated with increased perinatal mortality and increased risk of subsequent impaired neurological development. Due to high percentage of C/S in our country and the effect of anesthetic medications on umbilical blood gases which can cause ne...

متن کامل

The relationship between umbilical artery blood gas analysis and Apgar scores in neonates

  Extended Abstract Introduction and Background : in the first minutes of life it’s important to assess newborn condition very fast but effective and decide about medical intervention as needed. Umbilical artery blood gas analysis and Apgar scoring are the most common assessment systems which studies are trying to more sensitive and accurate way.in this study we compare Apgar scoring system an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of obstetrics and gynaecology

دوره 101 12  شماره 

صفحات  -

تاریخ انتشار 1994