Correction for the Flux Measurement Bias in X-ray Source Detection
نویسنده
چکیده
With a high spatial resolution imaging instrument such as the Chandra/ACIS, one can confidently identify an X-ray source with only a few detected counts. The detection threshold of such sources, however, varies strongly across the field-of-view of the instrument. Furthermore, the low detection counting statistics, together with a typical steep source number-flux relation, causes more intrinsically faint sources to be detected at apparently higher fluxes than the other way around. We quantify this “X-ray Eddington bias” as well as the detection threshold variation and devise simple procedures for their corrections. To illustrate our technique, we present results from our analysis of X-ray sources detected in the fields of the large-scale hierarchical complex Abell 2125 at z = 0.247 and the nearby galaxy NGC 4594 (Sombrero). We show that the sources detected in the Abell 2125 field, excluding 10 known complex members, have a numberflux relation consistent with the expected from foreground or background objects. In contrast, the number-flux relation of the NGC 4594 field is dominated by X-ray sources associated with the galaxy. This galactic component of the relation is well characterized by a broken power law. Subject headings: methods: data analysis — methods: statistical — galaxies: clusters: individual (Abell 2125) — galaxies: individual (NGC 4594) — X-rays: general — Xrays: galaxies
منابع مشابه
Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5
Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...
متن کاملFast UV detection by Cu-doped ZnO nanorod arrays chemically deposited on PET substrate
Well-aligned Cu-doped ZnO nanorods were successfully synthesized on polyethylene terephthalate (PET) substrate using chemical bath deposition method. The structural and optical properties of Cu-doped ZnO nanorods were investigated using X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), energy dispersive X-ray spectroscopy (EDX) and photoluminescence (PL) spectroscopy...
متن کاملDetermination of the flux of a neutron radioisotope source through gold activation method
Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...
متن کاملمقایسه گسیل یونی و پرتوی ایکس سخت بین نیتروژن و آرگون در دستگاه پلاسمای کانونی نوع مدر
In this study, some characteristics of a Mather type Plasma Focus (PF) device such as a discharge current, pinch time, ion flux and hard x-ray intensity has been investigated simultaneously in argon and nitrogen gases separately for various operating gas pressures and charging voltages of capacitor bank. It was observed that pinch phenomena was energy and pressure dependent in current sheath as...
متن کاملDevelopment of diamond-based X-ray detection for high-flux beamline diagnostics.
High-quality single-crystal and polycrystalline chemical-vapor-deposition diamond detectors with platinum contacts have been tested at the white-beam X28C beamline at the National Synchrotron Light Source under high-flux conditions. The voltage dependence of these devices has been measured under both DC and pulsed-bias conditions, establishing the presence or absence of photoconductive gain in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -