Evaluation of the dosimetric impact of loss and displacement of seeds in prostate low-dose-rate brachytherapy

نویسندگان

  • Yinkun Wang
  • Nicola J. Nasser
  • Jette Borg
  • Elantholi P. Saibishkumar
چکیده

PURPOSE To analyze the seed loss and displacement and their dosimetric impact in prostate low-dose-rate (LDR) brachytherapy while utilizing the combination of loose and stranded seeds. MATERIAL AND METHODS Two hundred and seventeen prostate cancer patients have been treated with LDR brachytherapy. Loose seeds were implanted in the prostate center and stranded seeds in the periphery of the gland. Patients were imaged with transrectal ultrasound before implant and with computerized tomography/magnetic resonance imaging (CT/MR) one month after implant. The seed loss and displacement had been analyzed. Their impact on prostate dosimetry had been examined. The seed distribution beyond the prostate inferior boundary had been studied. RESULTS The mean number of seeds per patient that were lost to lung, pelvis/abdomen, urine, or unknown destinations was 0.21, 0.13, 0.03, and 0.29, respectively. Overall, 40.1% of patients had seed loss. Seed migration to lung and pelvis/abdomen occurred in 15.5% and 10.5% of the patients, respectively. Documented seed loss to urine was found in 3% of the patients while 20% of patients had seed loss to unknown destinations. Prostate length difference between pre-plan and post-implant images was within 6 mm in more than 98% of cases. The difference in number of seeds inferior to prostate between pre-plan and post-implant dosimetry was within 7 seeds for 93% of patients. At time of implant, 98% of seeds, inferior to prostate, were within 5 mm and 100% within 15 mm, and in one month post-implant 83% within 9 mm and 96.3% within 15 mm. Prostate post-implant V100, D90, and rectal wall RV100 for patients without seed loss were 94.6%, 113.9%, and 0.98 cm(3), respectively, as compared to 95.0%, 114.8%, and 0.95 cm(3) for the group with seed loss. CONCLUSIONS Seed loss and displacement have been observed to be frequent. No correlation between seed loss and displacement and post-plan dosimetry has been reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Determination of Dosimetric Parameters of the Second Model of Pd-103 Seed Manufactured at Agricultural, Medical and Industrial Research School

Introduction: The use of low energy isotopes such as  103 Pd in brachytherapy for the treatment of cancers  such as prostate, eye, head, neck, breast and cervix is increasing. In this regard, different models of Pd- 103  seeds  have  been  designed  and  manufactured  at  the  Agricultural,  Medical  and  Industrial  Research  School (AMIRS) of Atomic Energy Organization of Iran. In this resear...

متن کامل

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

متن کامل

SU-E-T-465: Exploring the Dosimetric and Tumor Control Consequences of Prostate Seed Loss and Migration.

PURPOSE Once implanted, prostate brachytherapy seeds are vulnerable to loss and movement. A general estimation of these effects may be useful for making patient care decisions when seeds are lost after the post-implant scan. The goal of this work was to explore the dosimetric and radiobiological effects of the types of seed loss and migration common in prostate brachytherapy. METHODS This stu...

متن کامل

The investigation of prostatic calcifications using μ-PIXE analysis and their dosimetric effect in low dose rate brachytherapy treatments using Geant4.

Low dose rate brachytherapy is a widely used modality for the treatment of prostate cancer. Most clinical treatment planning systems currently in use approximate all tissue to water, neglecting the existence of inhomogeneities, such as calcifications. The presence of prostatic calcifications may perturb the dose due to the higher photoelectric effect cross section in comparison to water. This s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015