The effect of irrigation solutions on the apical sealing ability in different root canal sealers.
نویسندگان
چکیده
The aim of this study was to assess the effect of three root canal irrigation solutions on the apical sealing ability of three root canal obturation materials: gutta-percha/AH plus or MM-seal and Resilon/Epiphany SE. A total of 100 teeth with single straight root canals were randomly divided into three equal groups of 30 samples each, with the other 10 teeth (5 positive and 5 negative) used as controls. Each irrigation group was divided into three groups according to the use of three different root canal obturation materials (n = 10): Gutta-percha with AH plus or MM-seal, Resilon with Epiphany SE. The crowns were removed at the cementoenamel junction with a diamond disc under water coolant. The root canals were prepared using step-back technique and irrigation with either sodium hypochlorite (2.5%), chlorhexidine (2%), or MTAD solutions. The roots were obturated with lateral condensation technique using one of the obturation materials. The root surfaces was coated with two layer nail varnish (except apex), placed in 2% methylene blue dye solution, and centrifuged at 3,000 rpm for 5 minutes. Irrigation solutions affected the apical sealing ability of all the sealers. The chlorhexidine irrigation solution exhibited higher apical leakage values than did MTAD and NaOCl in all canal sealers, although the MTAD irrigation solution groups showed the least leakage values. The apical sealing ability of AH plus, Epiphany SE and MM-seal root canal sealers decreased when the chlorhexidine was used as an irrigation solution.
منابع مشابه
The effect of irrigating solutions on the apical sealing ability of MTA Fillapex and Adseal root canal sealers
Background. Maximum sealing ability or adhesion of endodontic sealers can be achieved after effective removal of the smear layer. Endodontic irrigants assist in adequate removal of the smear layer, improving the retention mechanism. The aim of this study was to evaluate the effect of two different root canal irrigation solutions (5.25% NaOCl followed by 17% EDTA and QMix) on the apical sealing ...
متن کاملEffect of different irrigation regimens on the evaluation of apical sealing ability of mineral trioxide aggregate
Introduction: This study aimed to evaluate and compare the apical sealing ability of different irrigation regimens (NaOCl, CHX, NS, and MTAD) . Methods: Seventy intact extracted single-rooted human teeth were selected. The roots were resected at 3 mm short of the apical foramen after access preparation. The canals were prepared with profile. This rotary file moved forward into the apical for...
متن کاملInfluence of Er:YAG laser irradiation on apical sealing of four different sealers.
The sealing of the root canal system is of fundamental importance for successful endodontic treatment. To obtain an adequate apical seal, many factors must be considered such as the presence of smear layer and the sealer applied. After canal preparation, this layer must be removed because it prevents close contact between the dentinal walls and the sealing material. The goal of this study was t...
متن کاملApical microleakage of different root canal sealers after use of maleic acid and EDTA as final irrigants.
This study aimed to compare the effects of ethylenediaminetetraacetic acid (EDTA) and maleic acid (MA) on the sealing ability of various root canal sealers. Eighty root canals were instrumented and irrigated with either EDTA or MA. They were divided into eight experimental groups and obturated as follows: Group 1: MA + Hybrid Root SEAL/gutta-percha. Group 2: EDTA + Hybrid Root SEAL/gutta-percha...
متن کاملEvaluation of the sealing ability of different root canal sealers: a combined SEM and micro-CT study
OBJECTIVE The purpose of this study was to analyze the ability of multiple compounds to seal the dental tubules using scanning electron microscopy (SEM) and micro-computed tomogra-phy (micro-CT). MATERIAL AND METHODS Twenty-four single-root human mandibular premolars were selected and instrumented with nickel-titanium rotary file and the final file size was #40/06. They were then randomly all...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian oral research
دوره 24 2 شماره
صفحات -
تاریخ انتشار 2010