Towards BirthAlert - A Clinical Device Intended for Early Preterm Birth Detection

نویسندگان

  • Mozziyar Etemadi
  • Philip Chung
  • J. Alex Heller
  • J. A. Liu
  • Larry Rand
  • Shuvo Roy
چکیده

Preterm birth causes 1 million infant deaths worldwide every year, making it the leading cause of infant mortality. Existing diagnostic tests such as transvaginal ultrasound or fetal fibronectin either cannot determine if preterm birth will occur in the future or can only predict the occurrence once cervical shortening has begun, at which point it is too late to reverse the accelerated parturition process. Using iterative and rapid prototyping techniques, we have developed an intravaginal proof-of-concept device that measures both cervical bioimpedance and cervical fluorescence to characterize microstructural changes in a pregnant woman's cervix in hopes of detecting preterm birth before macroscopic changes manifest in the tissue. If successful, such an early alert during this "silent phase" of the preterm birth syndrome may open a new window of opportunity for interventions that may reverse and avoid preterm birth altogether.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Treatment Response of Respiratory Distress Syndrome in Preterm Infants: Early Nasal Intermittent Positive Pressure Ventilation versus Early Nasal Continuous Positive Airway Pressure

Background Infant respiratory distress syndrome (IRDS) is one of the main causes of serious complications and death in preterm infants. Both Nasal Continuous Positive Airway Pressure (NCPAP) and Nasal Intermittent Positive Pressure Ventilation (NIPPV) are known as the most common treatment strategies for IRDS. The present study intended to compare NCPAP and NIPPV in the treatment of preterm inf...

متن کامل

A mathematical algorithm for detection of late-onset sepsis in very-low birth weight infants: a preliminary diagnostic test evaluation.

OBJECTIVE To study the diagnostic ability of RALIS (computerized mathematical algorithm and continuous monitoring device) to detect late onset sepsis among very low birth weight preterm neonates. METHODS Randomly chosen 24 very low birth weight infants with proven sepsis were compared to 22 infants without sepsis. The clinical parameters were retrospectively collected from the medical records...

متن کامل

The Value of Interleukin-8 and Interleukin-6 in Cervical Secretions as Predictors of Preterm Delivery

  Background and Objective: Preterm birth occurs in 8% to 11% of all pregnancies and is responsible for 75% to 80% of all neonatal deaths. Cytokines may be involved in the etiology of preterm birth through their stimulation of prostaglandin synthesis. Cytokines may be released intocervicovaginal fluid during the breakdown of the chorio-decidual adhesion or from an inflammatory reactio...

متن کامل

The Effect of Early Subcutaneous Administration of Erythropoietin on Hematopoiesis and Weight Gain Velocity in Preterm Infants

Abstract Introduction Anemia in preterm infants is identified as hemoglobin lower than 7-10g/dl around 1-3 months after birth. The aim of this study was to evaluate the effect of early subcutaneous administration of erythropoietin on hematopoiesis and weight gain velocity in preterm infants. Materials and Methods The present study was clinical trial carried out on 42 preterm infants. Those ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on bio-medical engineering

دوره 60 12  شماره 

صفحات  -