Accelerating free breathing myocardial perfusion MRI using multi coil radial k-t SLR.

نویسندگان

  • Sajan Goud Lingala
  • Edward DiBella
  • Ganesh Adluru
  • Christopher McGann
  • Mathews Jacob
چکیده

The clinical utility of myocardial perfusion MR imaging (MPI) is often restricted by the inability of current acquisition schemes to simultaneously achieve high spatio-temporal resolution, good volume coverage, and high signal to noise ratio. Moreover, many subjects often find it difficult to hold their breath for sufficiently long durations making it difficult to obtain reliable MPI data. Accelerated acquisition of free breathing MPI data can overcome some of these challenges. Recently, an algorithm termed as k - t SLR has been proposed to accelerate dynamic MRI by exploiting sparsity and low rank properties of dynamic MRI data. The main focus of this paper is to further improve k - t SLR and demonstrate its utility in considerably accelerating free breathing MPI. We extend its previous implementation to account for multi-coil radial MPI acquisitions. We perform k - t sampling experiments to compare different radial trajectories and determine the best sampling pattern. We also introduce a novel augmented Lagrangian framework to considerably improve the algorithm's convergence rate. The proposed algorithm is validated using free breathing rest and stress radial perfusion data sets from two normal subjects and one patient with ischemia. k - t SLR was observed to provide faithful reconstructions at high acceleration levels with minimal artifacts compared to existing MPI acceleration schemes such as spatio-temporal constrained reconstruction and k - t SPARSE/SENSE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated imaging of rest and stress myocardial perfusion MRI using multi-coil k-t SLR: a feasibility study

Background In myocardial perfusion imaging (MPI), highly accelerated acquisition can be used towards reducing the compromises in the image quality (spatio-temporal resolutions, volume coverage, SNR) routinely observed with the current clinical protocols. In this study, we demonstrate the feasibility of a recent accelerated dynamic MRI scheme, k-t SLR (based on sparse and low rank properties) (L...

متن کامل

Reconstruction of free-breathing myocardial perfusion MRI using simultanous modeling of perfusion and motion (SMPM) and arbitrary k-space sampling

INTRODUCTION: Respiratory motion of the heart represents a major practical problem in myocardial perfusion MRI. Firstly, the tracer kinetic models used for quantifying perfusion require that the myocardium remains stationary throughout the image time series, thus mandating a prior registration of the images. Secondly, modern k-space undersampling techniques, such as k-t BLAST [1] and UNFOLD [2]...

متن کامل

Split Bregman multicoil accelerated reconstruction technique: A new framework for rapid reconstruction of cardiac perfusion MRI.

PURPOSE Rapid reconstruction of undersampled multicoil MRI data with iterative constrained reconstruction method is a challenge. The authors sought to develop a new substitution based variable splitting algorithm for faster reconstruction of multicoil cardiac perfusion MRI data. METHODS The new method, split Bregman multicoil accelerated reconstruction technique (SMART), uses a combination of...

متن کامل

Accelerated first-pass perfusion MRI using BLOSM: Evaluation using dynamic simulations and patient datasets with prominent respiratory motion

k-t FOCUSS with ME/MC and k-t SLR. MSE for 26 magnitude-valued datasets (A) and for 12 complexvalued datasets (B) showed that BLOSM achieved the minimum error. BLOSM also achieved the lowest error at all acceleration rates (C). (* P<0.01 BLOSM vs. the other methods, ANOVA; ** P<0.01 BLOSM vs. all the other methods, paired Student’s t-test) Figure 2. Example images at two time points (rows 1 and...

متن کامل

A patient-adapted navigator tracking approach for prospective 3D respiratory motion correction in free-breathing myocardial perfusion imaging

H. Pedersen, S. Ringgaard, W. Y. Kim The MR Research Centre, Skejby Hospital, Aarhus University Hospital, Aarhus N, Denmark INTRODUCTION Quantitative analysis of myocardial perfusion using free-breathing first-pass perfusion MRI is degraded by respiratory induced motion of the heart. Conventional strategies to correct this motion include the manual alignment of each image to fit a reference ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 58 20  شماره 

صفحات  -

تاریخ انتشار 2013