Calibration of Infra-red CO(2) Gas Analyzers.
نویسندگان
چکیده
Precision gas mixing pumps produce CO(2) gas mixtures for the calibration of infra-red CO(2) gas analyzers equivalent in accuracy to the standard CO(2) gas mixtures (+/- 1%) supplied by the National Bureau of Standards, Washington, D. C.The calibration of infra-red gas analyzers by the pressure difference method and by concentration differences did not agree. A factor of 0.709 was necessary to correct the pressure difference method for the effects of pressure broadening with our analyzer.
منابع مشابه
The effect of nitrous oxide on the measurement of single-breath transfer factor.
One hour after a bone marrow biopsy and inhalation of Entonox gas (50% nitrous oxide (N2O) and 50% oxygen), a patient had a markedly reduced transfer factor of the lung for carbon monoxide (TL,CO). Three hours after Entonox, the patient had a normal TL,CO. Since carbon monoxide (CO) and N2O have similar spectral wavelengths, it was proposed that residual N2O in the lungs was interfering with th...
متن کاملAdvancement of an Infra-Red Technique for Whole-Field Concentration Measurements in Fluidized Beds
For a better understanding and description of the mass transport phenomena in dense multiphase gas-solids systems such as fluidized bed reactors, detailed and quantitative experimental data on the concentration profiles is required, which demands advanced non-invasive concentration monitoring techniques with a high spatial and temporal resolution. A novel technique based on the selective detect...
متن کاملBlood Gas and Critical Care Analyte Analysis
point of care (POC) in critical care areas such as the emergency department, neonatal and adult medical intensive care units, surgical intensive care units, and the operating room.2 The collection and analysis by portable or standard blood gas machines at or near the point of care minimizes the time needed to obtain and report laboratory values, which facilitates timely evaluation of results an...
متن کاملIt is time to examine process stream analysis
The number of laboratory methods for the analysis of samples from process streams has increased tremendously so that the analytical chemist need only review the literature to find one suitable for his application..The literature cites many methods by gas and liquid chromatography, atomic absorption , infra-red, ion chromatography, etc. The direct application of analytical methods to continuous ...
متن کاملMeris In-flight Spectral Calibration
This paper first describes the different activities conducted for MERIS regarding it’s spectral calibration. The onboard spectral calibration is based on the use of a panel which presents well defined absorption peaks. In this absorption bands, each MERIS detector is characterized in wavelength. Limitations of this method are in the near infra red because of the lack of absorption lines in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Plant physiology
دوره 44 8 شماره
صفحات -
تاریخ انتشار 1969