Automatically tuned and matched RF transceive head coil at 7T

نویسندگان

  • Sung-Min Sohn
  • Lance DelaBarre
  • Anand Gopinath
  • J.Thomas Vaughan
چکیده

Introduction The transmit efficiency and receive signal-to-noise ratio (SNR) of transceive RF coils depends on how well the resonance circuit is tuned to the Larmor frequency and matched to the 50 ohm coaxial cable. Patient size variability changes the load the coil couples with and adversely impacts both tuning and matching, and subsequently the power efficiency and SNR of the coil. The loading effects from different human bodies are unpredictable and problematic. Significantly mismatched coils stress other RF components with reflected power like T/R switches and RF power amplifiers. Conventional manual re-tuning and re-matching of coils between dissimilar body types is timeconsuming and impractical for clinic applications. Furthermore, at ultra-high fields, multi-channel coils aggravate the loading problem because: 1) the time required for re-tuning/matching is proportional to the number of channels and 2) the loading effects significantly change S11 (the reflection coefficient) and the associated RF power efficiency. Previous efforts to automatically tune and match coils focused only on receive coils because transmit or transceiver coils must handle kilowatts, not microwatts of power, a difficult engineering challenge. This study offers an electrically driven stand-alone automatic tuning and matching system for RF transmit and/or receive coils.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 7T ′′Capless′′ Transceive Breast Coil

Introduction Apart from being a non-invasive imaging modality, MR breast imaging can also provide high spatial and temporal resolution images of the breast, which is advantageous for fast and accurate diagnosis of disease. Studies have shown that it is possible to acquire high resolution breast images at ultra high fields with dedicated transceive RF breast coils that can transmit homogenous lo...

متن کامل

Transceive Stripline Arrays for Ultra High Field Parallel Imaging Applications

G. Adriany, P. Van de Moortele, F. Wiesinger, P. Andersen, J. Strupp, X. Zhang, C. J. Snyder, W. Chen, K. P. Pruessmann, P. Boesiger, J. T. Vaughan, K. Ugurbil Center for MR Research, University of Minnesota Medical School, Minneapolis, United States, Institute for Biomedical Engineering, University and ETH Zurich, Switzerland We present four and eight channel transceive stripline arrays for ul...

متن کامل

SENSE optimization of a transceive surface coil array for MRI at 4 T.

Parallel imaging (PI) techniques employ the use of multiple radiofrequency (RF) channels to transmit and/or receive the NMR signal. In the current study we use a finite difference time domain (FDTD) method to simulate the electromagnetic fields of a RF coil array operating in transmit-receive (transceive) mode and receive-only mode. Optimization of these configurations for PI is studied as well...

متن کامل

A Concentrically Shielded Transceive Array Coil Optimized for B1+ Inhomogeneity Correction at 7T

Introduction: A multiple channel transceive array offers the possibility for flexible mitigation of the transmit inhomogeneity at high fields through either B1 + shimming or by the use of spatially tailored RF excitation pulses accelerated to useful durations using parallel transmit (pTx). Accelerating the transmit RF pulses requires a distinct spatial sensitivity profile. One of the major prob...

متن کامل

Automated tuning of an eight-channel cardiac transceive array at 7 tesla using piezoelectric actuators

PURPOSE Ultra-high field (UHF) MR scanning in the body requires novel coil designs due to B1 field inhomogeneities. In the transverse electromagnetic field (TEM) design, maximum B1 transmit power can only be achieved if each individual transmit element is tuned and matched for different coil loads, which requires a considerable amount of valuable scanner time. METHODS An integrated system for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013