Development and prospective evaluation of an automated software system for quality control of quantitative 99mTc-MAG3 renal studies.
نویسندگان
چکیده
UNLABELLED Quantitative nuclear renography has numerous potential sources of error. We previously reported the initial development of a computer software module for comprehensively addressing the issue of quality control (QC) in the analysis of radionuclide renal images. The objective of this study was to prospectively test the QC software. METHODS The QC software works in conjunction with standard quantitative renal image analysis using a renal quantification program. The software saves a text file that summarizes QC findings as possible errors in user-entered values, calculated values that may be unreliable because of the patient's clinical condition, and problems relating to acquisition or processing. To test the QC software, a technologist not involved in software development processed 83 consecutive nontransplant clinical studies. The QC findings of the software were then tabulated. QC events were defined as technical (study descriptors that were out of range or were entered and then changed, unusually sized or positioned regions of interest, or missing frames in the dynamic image set) or clinical (calculated functional values judged to be erroneous or unreliable). RESULTS Technical QC events were identified in 36 (43%) of 83 studies. Clinical QC events were identified in 37 (45%) of 83 studies. Specific QC events included starting the camera after the bolus had reached the kidney, dose infiltration, oversubtraction of background activity, and missing frames in the dynamic image set. CONCLUSION QC software has been developed to automatically verify user input, monitor calculation of renal functional parameters, summarize QC findings, and flag potentially unreliable values for the nuclear medicine physician. Incorporation of automated QC features into commercial or local renal software can reduce errors and improve technologist performance and should improve the efficiency and accuracy of image interpretation.
منابع مشابه
Synthesis, formulation and quality control of 99mTc-MAG3, as a renal tubular 99mTc-radiopharmaceutical kit [Persian]
Radionuclidic techniques may provide assessment of glomerular filtration rate (GFR) effective renal plasma flow (ERPF) or individual renal function. Several agents were available for determination of these parameters such as ¹³¹I-OIH (O-iodohippurate) and different derivatives of DADS (Diamidodisulfur). OIH has the disadvantage of imparting a relatively high absorbed radiation dose to the...
متن کاملA camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]
Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...
متن کاملRENEX: an expert system for the interpretation of 99mTc-MAG3 scans to detect renal obstruction.
UNLABELLED A renal expert system (RENEX) has been developed to assist physicians detect renal obstruction in patients undergoing pre- and postfurosemide 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) scans. RENEX uses quantitative parameters extracted from the dynamic renal scan data and heuristic rules in the form of a knowledge base (KB) obtained from expert interpreters to conclude whether a ki...
متن کامل99mTc-MAG3: review of pharmacokinetics, clinical application to renal diseases and quantification of renal function.
About 14 years have passed since Fritzberg et al. developed 99mTc-MAG3 in 1986. The biological properties of this radiopharmaceutical are somewhat different from radioiodine labeled hippurate: it exhibits higher protein binding, slower blood clearance, higher extraction efficiency by tubular cells and larger excretion into the bile than the latter. Nonetheless, it has been widely used as the ag...
متن کاملAssessment of renal function in mice with unilateral ureteral obstruction using 99mTc-MAG3 dynamic scintigraphy
BACKGROUND Renal scintigraphy using 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) is widely used for the assessment of renal function in humans. However, the application of this method to animal models of renal disease is currently limited, especially in rodents. Here, we have applied 99mTc-MAG3 renal scintigraphy to a mouse model of unilateral ureteral obstruction (UUO) and evaluated its utility...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine technology
دوره 35 1 شماره
صفحات -
تاریخ انتشار 2007