Strategies for Low Accelerating Voltage X-ray Microanalysis of Sub-Micrometer Features with the FE-EPMA
نویسندگان
چکیده
X-ray microanalyses of sub-micrometer features require that a lower accelerating voltage be used. This reduction in the accelerating voltage reduces the penetrating distance of the beam electrons and thereby reduces the analytical volume. Two general strategies have been proposed for achieving the smallest analytical volume. The first approach involves significantly reducing the accelerating voltage to minimize the electron interaction volume. For many element systems, the optimum accelerating voltage is in the 5-8kV range, assuming a field emission electron gun is used for the analysis. A lower kV will reduce the penetrating depth of the electrons further. However with lower kV, the diameter of the electron beam becomes a critical factor in determining the analytical area, and with a lower kV, the beam diameter becomes larger. Mostly this comes from the higher required beam current used due to the lower X-ray production rate at the lower kV. This low-kV strategy also typically requires a different set of X-ray lines be used, since some of the more commonly used X-ray lines are not generated at these lower accelerating voltages. However, it can produce a very small analytical volume (Fig. 1a).
منابع مشابه
Low-voltage electron-probe microanalysis of Fe-Si compounds using soft X-rays.
Conventional electron-probe microanalysis has an X-ray analytical spatial resolution on the order of 1-4 μm width/depth. Many of the naturally occurring Fe-Si compounds analyzed in this study are smaller than 1 μm in size, requiring the use of lower accelerating potentials and nonstandard X-ray lines for analysis. Problems with the use of low-energy X-ray lines (soft X-rays) of iron for quantit...
متن کاملDetermination of the composition of Ultra-thin Ni-Si films on Si: constrained modeling of electron probe microanalysis and x-ray reflectivity data
The homogeneous bulk assumption used in traditional electron probe microanalysis (EPMA) can be applied for thin-layered systems with individual layers as thick as 50 nm provided the penetration depth of the lowest accelerating voltage exceeds the total film thickness. Analysis of an NIST Ni-Cr thin film standard on Si using the homogeneous model yielded certified compositions and application of...
متن کاملElectron Probe Microanalysis (EPMA)
An electron microprobe is an electron microscope designed for the non-destructive x-ray microanalysis and imaging of solid materials. It is essentially a hybrid instrument combining the capabilities of both the scanning electron microscope (SEM) and an x-ray fluorescence spectrometer (XRF), with the added features of fine-spot focusing (~ 1 micrometer), optical microscope imaging, and precision...
متن کاملMonte Carlo Simulation of Characteristic Secondary Fluorescence in Electron Probe Microanalysis of Homogeneous Samples Using the Splitting Technique.
Electron probe microanalysis (EPMA) is based on the comparison of characteristic intensities induced by monoenergetic electrons. When the electron beam ionizes inner atomic shells and these ionizations cause the emission of characteristic X-rays, secondary fluorescence can occur, originating from ionizations induced by X-ray photons produced by the primary electron interactions. As detectors ar...
متن کاملAnalytical Challenges and Strategies in FE-EPMA
Unquestionably, since their introduction one decade ago, field emission (FE) electron microprobes have pushed the boundaries of electron probe microanalysis (EPMA) by offering new possibilities to characterize smaller features. As with conventional microprobes, the proper selection of the analytical conditions (beam energy, beam current, acquisition time, x-ray line) is essential to obtain an a...