Cryostat Slice Irregularities May Introduce Bias in Tissue Thickness Estimation: Relevance for Cell Counting Methods.
نویسندگان
چکیده
Stereological techniques using the optical disectors require estimation of final section thickness, but frozen tissue irregularities may interfere with this estimation. Cryostat slices from rodent nerve tissues (dorsal root ganglia, spinal cord, and brain), cut at 16, 40, and 50 μm, were digitized with a confocal microscope and visualized through 3D software. Geometric section thickness of tissue (T geom) was defined as tissue volume/area. Maximal section thicknesses (T max), from the top to the bottom of the section, were measured in a random sample of vertical ZX planes. Irregularities were mostly related to blood vessels traversing the tissue and neuronal somas protruding over the cut surfaces, with other neuron profiles showing a fragmented appearance. Irregularities contributed to increasing the distance between the tops and bottoms of slices sectioned in different laboratories. Significant differences were found between T max and T geom for all thickness studies and counting frames (p<0.01). The T geom/T max average rate was 68.4-85.7% in volumes around cell profiles (∼600-1,200 μm2) and 83.3-91.8% in subcellular samples (∼25-160 μm2). Confocal microscopy may help to assess tissue irregularities, which might lead to an overestimation of tissue volume if section thickness is estimated by focusing on the top and bottom of the sections.
منابع مشابه
Thin Sectioning of Slice Preparations for Immunohistochemistry
Many investigations in neuroscience, as well as other disciplines, involve studying small, yet macroscopic pieces or sections of tissue that have been preserved, freshly removed, or excised but kept viable, as in slice preparations of brain tissue. Subsequent microscopic studies of this material can be challenging, as the tissue samples may be difficult to handle. Demonstrated here is a method ...
متن کاملIs frozen sections an advantage for unbiased stereological methods ?
References [1] West MJ. New stereological methods for counting neurons. Analysis of cell death in the trochlear nucleus of the chick embryo: calibration of the optical dissector counting method reveals systematic bias. Differential tissue shrinkage and compression in the z-axis: implications for optical dissector counting in vibratome, plastic and cryosections. Use of cryostat sections from sna...
متن کاملMetric Characteristics of Various Methods for Numerical Density Estimation in Transmission Light Microscopy – a Computer Simulation
In the introduction the evolution of methods for numerical density estimation of particles is presented shortly. Three pairs of methods have been analysed and compared: (1) classical methods for particles counting in thin and thick sections, (2) original and modified differential counting methods and (3) physical and optical disector methods. Metric characteristics such as accuracy, efficiency,...
متن کاملInvestigation of the effect of slice thickness and Kvp changes on the accuracy of linear measurements in CBCT: In vitro study
Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...
متن کاملEffect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada
دوره 21 4 شماره
صفحات -
تاریخ انتشار 2015