Improving Light-Load Efficiency of AC/DC Boost PFC Converters by Nonlinear Control Scheme
نویسنده
چکیده
Power supply units (PSUs) with an equally shared load current are widely employed for data processing equipment like servers due to their advantages such as easy extension of power processing capability and simple thermal management. This paper presents a method to improve light-load efficiency by reducing load-independent losses such as capacitive turn-on and core losses and reduce the THD of input current of a boost PFC converter used in applications to high performance server power supply units. The conventional system constant frequency and average current mode control scheme will result lower efficiency and high THD current distortion under light load operation. To overcome this problem, this paper proposes a digital multi-mode control scheme with variable switching frequency control. A nonlinear control scheme with gain scheduling has been used to improve dynamic response under light load condition with discontinuous conduction mode (DCM) operation with lower switching frequency.
منابع مشابه
Boost Converter for Power Factor Correction of DC Motor Drive
With the increasing demand for power from the ac line and more stringent limits for power quality, power factor correction has gained great attention in recent years. A variety of circuit topologies and control methods have been developed for the PFC application. While the discontinuous conduction mode (DCM) converters such as boost and flyback converters are well suited for low power applicati...
متن کاملGeneralized Average-current-mode Control of Single-phase Ac-dc Boost Converters with Power Factor Correction
The dissertation presents a generalized average-current-mode control technique (GACMC), which is an extension of the average-current-mode control (ACMC) for single-phase ac-dc boost converters with power factor correction (PFC). Traditional ACMC is generalized in a sense that it offers improved performance in the form of significant reduction of the current control loop bandwidth requirement fo...
متن کاملPower Factor Correction Using Step-Up Chopper Fed to a DC Motor Drive
With the expanding interest for power from the ac line and more stringent cutoff points for power quality, power factor correction is extraordinary consideration as of late. An assortment of circuit topologies and control strategies has been created for the PFC application. While the discontinuous conduction mode (DCM) converters for example, boost and fly back converters are appropriate for lo...
متن کاملA New Structure of Buck-Boost Z-Source Converter Based on Z-H Converter
In this paper, a new structure for buck-boost Z-source converter based on Z-H topology is proposed. The proposed converter consists of two LC networks similar to the conventional Z-source and Z-H converters. One of the characteristics of the proposed structure is that, without any changing in its’ power circuit, it can be used in different conversions such as dc/dc, dc/ac and ac/ac. This unique...
متن کاملDesign Guideline on 150W Power Supply for LED
This application note describes a 150W rating design guideline for LED street lighting. The application design consists of CRM PFC and LLC SRC with high power factor and high power conversion efficiency using FL7930B and FAN7621S. To verify the validity of the application board and scheme, a demonstration board 150W (103V/1.46A) AC-DC converter was implemented and its results are presented in t...
متن کامل