Fluid intake, hydration, work physiology of wildfire fighters working in the heat over consecutive days.
نویسندگان
چکیده
PURPOSE (i) To evaluate firefighters' pre- and post-shift hydration status across two shifts of wildfire suppression work in hot weather conditions. (ii) To document firefighters' fluid intake during and between two shifts of wildfire suppression work. (iii) To compare firefighters' heart rate, activity, rating of perceived exertion (RPE), and core temperature across the two consecutive shifts of wildfire suppression work. METHOD Across two consecutive days, 12 salaried firefighters' hydration status was measured immediately pre- and post-shift. Hydration status was also measured 2h post-shift. RPE was also measured immediately post-shift on each day. Work activity, heart rate, and core temperature were logged continuously during each shift. Ten firefighters also manually recorded their food and fluid intake before, during, and after both fireground shifts. RESULTS Firefighters were not euhydrated at all measurement points on Day one (292±1 mOsm l(-1)) and euhydrated across these same time points on Day two (289±0.5 mOsm l(-1)). Fluid consumption following firefighters' shift on Day one (1792±1134ml) trended (P = 0.08) higher than Day two (1108±1142ml). Daily total fluid intake was not different (P = 0.27), averaging 6443±1941ml across both days. Core temperature and the time spent ≥ 70%HRmax were both elevated on Day one (when firefighters were not euhydrated). Firefighters' work activity profile was not different between both days of work. CONCLUSION There was no difference in firefighters' pre- to post-shift hydration within each shift, suggesting ad libitum drinking was at least sufficient to maintain pre-shift hydration status, even in hot conditions. Firefighters' relative hypohydration on Day one (despite a slightly lower ambient temperature) may have been associated with elevations in core temperature, more time in the higher heart rate zones, and 'post-shift' RPE.
منابع مشابه
Multiple Days of Heat Exposure on Firefighters’ Work Performance and Physiology
This study assessed the accumulated effect of ambient heat on the performance of, and physiological and perceptual responses to, intermittent, simulated wildfire fighting tasks over three consecutive days. Firefighters (n = 36) were matched and allocated to either the CON (19°C) or HOT (33°C) condition. They performed three days of intermittent, self-paced simulated firefighting work, intersper...
متن کاملThe Impact of Heat Exposure and Sleep Restriction on Firefighters’ Work Performance and Physiology during Simulated Wildfire Suppression
This study was designed to examine the effects of ambient heat on firefighters' physical task performance, and physiological and perceptual responses when sleep restricted during simulated wildfire conditions. Thirty firefighters were randomly allocated to the sleep restricted (n = 17, SR; 19 °C, 4-h sleep opportunity) or hot and sleep restricted (n = 13, HOT + SR; 33 °C, 4-h sleep opportunity)...
متن کاملComparison of fluid balance between competitive swimmers and less active adolescents.
The aim of this study was to compare daily hydration profiles of competitive adolescent swimmers and less active maturation- and sex-matched controls. Hydration profiles of 35 competitive adolescent swimmers (male n = 18, female n = 17) and 41 controls (male n = 29, female n = 12) were monitored on 4 consecutive days. First morning hydration status was determined independently by urine specific...
متن کاملHydration, Fluid Intake, and Related Urine Biomarkers among Male College Students in Cangzhou, China: A Cross-Sectional Study—Applications for Assessing Fluid Intake and Adequate Water Intake
The objectives of this study were to assess the associations between fluid intake and urine biomarkers and to determine daily total fluid intake for assessing hydration status for male college students. A total of 68 male college students aged 18-25 years recruited from Cangzhou, China completed a 7-day cross-sectional study. From day 1 to day 7; all subjects were asked to complete a self-admin...
متن کاملتعیین و مقایسه شاخص های حرارتی TWLو WBGT در کارکنان یک دکل خشکی نفت-گاز در اهواز
Background and aims: Health hazards under heat stress conditions are well known and many industrial workers expose to heat stressful environments. Protection of the health of workers with suitable productivity is very important the idea requires adoption of a heat stress index that is both reliable and easy to use. Recent studies have found that Thermal Work Limit (TWL) performs better than W...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 59 5 شماره
صفحات -
تاریخ انتشار 2015