Prediction of hemodynamics under left ventricular assist device.
نویسندگان
چکیده
Left ventricular assist device (LVAD) saves lives in patients with severe left ventricular (LV) failure. However, predicting how much LVAD boosts total cardiac output (CO) remains difficult. This study aimed to develop a framework to quantitatively predict the impact of LVAD on hemodynamics. We adopted the circulatory equilibrium framework and incorporated LVAD into the integrated CO curve to derive the circulatory equilibrium. In anesthetized dogs, we ligated left coronary arteries to create LV failure and inserted a centrifugal pump as LVAD. Using CO and right (PRA) and left atrial pressure (PLA) measured before LVAD support, we predetermined the stressed volume (V) and logarithmic slope of right heart CO curve (SR). Next, we initiated LVAD at maximum level and then decreased LVAD flow stepwise while monitoring hemodynamic changes. We predicted LVAD-induced CO and PRA for given PLA from the predetermined SR and V and compared with those measured experimentally. The predicted CO [r2 = 0.907, SE of estimate (SEE) = 5.59 ml·min-1·kg-1, P < 0.001] and PRA (r2 = 0.967, SEE = 0.307 mmHg, P < 0.001) matched well with measured values indicating the validity of the proposed framework. We further conducted simulation using the validated framework to analyze the impact of LVAD on PRA under various right ventricular (RV) functions. It indicated that PRA is relatively insensitive to changes in RV end-systolic elastance or pulmonary arterial resistance, but sensitive to changes in V. In conclusion, the circulatory equilibrium framework predicts quantitatively the hemodynamic impact of LVAD. This knowledge would contribute to safe management of patients with LV failure undergoing LVAD implantation. NEW & NOTEWORTHY Hemodynamic response to left ventricular assist device (LVAD) has not been quantitatively investigated. This is the first report of quantitative prediction of the hemodynamics on LVAD using circulatory equilibrium framework. The validated framework allows us to simulate the impact of LVAD on right atrial pressure under various right ventricular functions.
منابع مشابه
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملEffects of a left ventricular assist device with a centrifugal pump on left ventricular diastolic hemodynamics.
The purpose of this investigation was to analyze how left ventricular assist device (LVAD) with a centrifugal pump alters left ventricular diastolic hemodynamics and energy by means of a left ventricular pressure volume relationship. Fifteen anesthetized normal pig hearts were studied after placement of an apical drainage LVAD with a centrifugal pump. Indices of the left ventricular isovolumic ...
متن کاملAtypical tamponade hemodynamic in a patient with temporary left ventricular assist device.
Postoperative bleeding and tamponade are considered major complications after implantation of left ventricular assist devices. Firstly, 40% of patients supported by ventricular assist devices experience early postoperative bleeding, and 20% developed tamponade requiring re-exploration. Secondly, we present a case of a patient with tamponade, on temporary left ventricular assist device (LVAD) su...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 312 1 شماره
صفحات -
تاریخ انتشار 2017