Determination of parameters of left ventricular diastolic filling with pulsed Doppler echocardiography: comparison with cineangiography.

نویسندگان

  • R Rokey
  • L C Kuo
  • W A Zoghbi
  • M C Limacher
  • M A Quinones
چکیده

To determine the relationship between Doppler-derived flow velocity through the mitral anulus and angiographic parameters of left ventricular filling, 30 patients were studied by two-dimensional echocardiography combined with pulsed Doppler echocardiography followed within 1 hr by left ventricular angiography. The average heart rate for each test was 69 beats/min. Doppler-derived parameters included: early peak diastolic velocity (E) and peak atrial velocity, peak filling rate computed as E X cross-sectional area of the mitral anulus derived from the annular diameter, normalized peak filling rate computed as peak filling rate divided by the left ventricular end-diastolic volume determined by two-dimensional echocardiography, and half filling fraction derived from the time-velocity integral of the Doppler-determined velocity curve. Frame-by-frame left ventricular volumes were obtained throughout diastole from single-plane cineangiograms. A volume-time curve with its derivative was generated by computer processing from which peak filling rate, normalized peak filling rate, and half filling fraction were measured. Morphologically, the Doppler-derived velocity profile resembled the derivative of the angiographic volume curve. In patients with reduced angiographic peak filling rates, early peak diastolic velocity was often decreased less than 45 cm/sec with a relative increase in peak atrial velocity resulting in an early peak diastolic velocity to peak atrial velocity ratio less than 1.0. There were no significant differences in mean values for peak filling rate, normalized peak filling rate, and half filling fraction by Doppler echocardiography vs angiography (296 vs 283 ml/sec, 1.9 vs 2.0 sec-1 and 0.55 vs 0.55, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

متن کامل

Doppler-echocardiographic characteristics of left ventricular function in patients with pseudoexfoliation glaucoma: a preliminary report.

Glaucoma is associated with an increased incidence of cardiovascular disease and risk factors. The aim of the study was to assess the left ventricular (LV) function in patients with pseudoexfoliation (PEX) glaucoma using doppler-echocardiographic examinations. Two-dimensional and pulsed Doppler echocardiography of transmitral flow was performed in 21 patients with (PEX) glaucoma and 24 controls...

متن کامل

Left ventricular filling in hypertrophic cardiomyopathy: a pulsed Doppler echocardiographic study.

Abnormal left ventricular diastolic properties have been described in patients with hypertrophic cardiomyopathy. To evaluate the diastolic filling characteristics of the left ventricle in patients with this disease, pulsed Doppler echocardiography was used to study mitral flow velocity in 17 patients with hypertrophic cardiomyopathy (11 with and 6 without systolic anterior motion of the mitral ...

متن کامل

LEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION

In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 71 3  شماره 

صفحات  -

تاریخ انتشار 1985