Urea as a recovery marker for quantitative assessment of tumor interstitial solutes with microdialysis.
نویسندگان
چکیده
Microdialysis is a technique that enables measurement of extracellular concentrations of unbound analytes. A small probe with a semipermeable membrane is implanted in tissue and constantly perfused. Small analytes in the interstitial fluid diffuse into the perfusate and are collected. Often, microdialysate concentrations of an analyte are only a fraction of the unbound concentrations in the extracellular space attributable to incomplete equilibration between these two compartments. Thus, it is necessary to determine the degree of equilibration between microdialysate and interstitium for each probe to accurately estimate concentrations. In this study, we investigated tissue urea as a solute to continually correct for nonequilibrium conditions. We used this method, along with relative diffusivities of urea and glucose, to monitor glucose levels before and during hyperglycemia as an example of how this method can be applied. No-net-flux experiments were performed on 10 anesthetized female rats with mammary adenocarcinomas. Microdialysis probes 1 cm in length with a molecular weight cutoff of M(r) 100,000 were used. Urea was added to the perfusate in concentrations of 0.83, 2.5, 5.0, and 13.33 mM. Microdialysate samples were collected every 15 min. For each rat, there was a linear relationship between the net urea concentration (outflow-inflow) and the urea concentration in the perfusate (inflow). Net flux should equal zero when perfusate and interstitial concentrations are equal. In an additional series of 13 rats, microdialysate samples were obtained before, during, and after administration of glucose at a dose of 1 g/kg. The interstitial tumor urea concentration was 7.8 +/- 0.3 mM compared with 6.2+/- 0.3 mM in plasma. There was a significant linear relationship between plasma urea (measured directly) and tumor urea (microdialysis measurement). Plasma urea concentrations were constant over time in all of the experiments, including those where hyperglycemia was induced. Hyperglycemia caused 7.7- and 3.6-fold increases in tumor and plasma glucose, respectively. There was no effect of hyperglycemia on tumor blood flow. Urea appears to be a useful low molecular weight relative recovery marker for tumor microdialysis. In combination with the determination of relative diffusivity between urea and the solute of interest, this calibration method may allow for quantitative measurements of tumor metabolites and unbound drugs.
منابع مشابه
A modified in vivo flow variation technique of microdialysis for sampling uremic toxins in the subcutaneous interstitial compartment.
BACKGROUND Uremic toxins are typically measured in plasma and little is known of their interstitial concentrations. We undertook experiments to validate a microdialysis technique for simultaneous recovery of small and large uremic toxins in the subcutaneous interstitial fluid (ISF). METHODS Microdialysis catheters were inserted into the subcutaneous interstitium of 8 subjects (controls and ur...
متن کاملA Modified in vivo Flow Variation Technique of Microdialysis for Sampling Uremic Toxins in the Subcutaneous Interstitial Compartment
Background: Uremic toxins are typically measured in plasma and little is known of their interstitial concentrations. We undertook experiments to validate a microdialysis technique for simultaneous recovery of small and large uremic toxins in the subcutaneous interstitial fluid (ISF). Methods: Microdialysis catheters were inserted into the subcutaneous interstitium of 8 subjects (controls and ur...
متن کاملEvaluation of Sensitivity and Specificity of Urine Survivin As A New Molecular Marker in Diagnosis of Bladder Tumors
Bladder cancer is one of the most common forms of cancers in the world. The current gold standards for itsdiagnosis are cystoscopy and urine cytology. Cystoscopy, a naked eye assessment of the bladder, is invasive, uncomfortable and costly with a great deal of personal variability in its results; while urine cytology has high specificity but low sensitivity, particularly for low-grade les...
متن کاملInterstitial glycerol as a marker for membrane phospholipid degradation in the acutely injured human brain.
OBJECTIVE Brain interstitial glycerol was studied as a potential marker for membrane phospholipid degradation in acute human brain injury. METHODS Glycerol was measured in microdialysis samples from the frontal lobe cortex in four patients in the neurointensive care unit, during the acute phase after severe aneurysmal subarachnoid haemorrhage. Microdialysis probes were inserted in conjunction...
متن کاملMuscle interstitial glucose and lactate levels during dynamic exercise in humans determined by microdialysis.
The purpose of the present study was to use the microdialysis technique to determine skeletal muscle interstitial glucose and lactate concentrations during dynamic incremental exercise in humans. Microdialysis probes were inserted into the vastus lateralis muscle, and subjects performed knee extensor exercise at workloads of 10, 20, 30, 40, and 50 W. The in vivo probe recoveries determined at r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cancer research
دوره 61 21 شماره
صفحات -
تاریخ انتشار 2001