[Automatic measurement of dye filling of simultaneous digital ICG- and fluorescein angiography sequences].

نویسندگان

  • B Török
  • R Hirschi
  • G Székely
  • C Brechbühler
  • L Blass
  • K Barabás
  • P Bischoff
چکیده

BACKGROUND The ICG filling is supposed to be faster than Fluorescein filling. Interestingly the filling characteristics of these dyes were never correlated directly using precise quantitative methods. Since ICG and Fluorescein are injected as a mixture, the simultaneous 2-channel angiography provides a suitable method to correlate the filling characteristics of the dyes. MATERIAL AND METHODS The simultaneous ICG and Fluorescein angiograms were recorded with a Rodenstock Scanning Laser Ophthalmoscope. The angiographic images were digitized real-time with a graphic workstation. Filling characteristics of the two dyes was calculated after off-line eye tracking in different regions of interests (ROIs) on the central retina. RESULTS The Fluorescein filling was faster than the ICG filling in 56.5% of our patients. In 26% of our patients was a mixed filling detectable. Depending on the position of the ROIs the Fluorescein or ICG filling was faster. In only 17.5% of our cases was the ICG filling faster than the Fluorescein filling. CONCLUSION Our results show that Fluorescein filling in more than 50% of the cases is faster than ICG filling and only a minority of the patients has a faster ICG filling. According to our experience the filling pattern of the two dyes is individual, there is no rule of thumb for the filling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous indocyanine green and fluorescein angiography.

PURPOSE To facilitate the interpretation of the choroidal dye filling sequence, the use of simultaneous indocyanine green (ICG) and fluorescein angiography was evaluated. METHODS A single-wavelength scanning laser ophthalmoscope (SLO) was modified to a two-wavelength system, permitting the simultaneous recording of ICG and fluorescein angiography. This method has been used in 340 cases. About...

متن کامل

Features of abnormal choroidal circulation in central serous chorioretinopathy.

AIMS To evaluate abnormalities in the choroidal circulation in cases of central serous chorioretinopathy (CSC). METHODS A complete clinical ophthalmological examination was performed using simultaneous fluorescein and indocyanine green (ICG) angiography with a confocal scanning laser ophthalmoscopy and the digital images analysed in 36 consecutive patients with acute CSC. To quantify the chor...

متن کامل

EXTENDED REPORT Lower limits of fluorescein and indocyanine green dye for digital cSLO fluorescence angiography

Background: With the advent of digital confocal scanning laser ophthalmoscopy it is possible to detect low levels of fluorescence. Here we used a novel confocal scanning laser ophthalmoscope (cSLO) to determine lower limits of dye required for fluorescein (FL) and indocyanine green (ICG) angiography. Methods: A cSLO (Heidelberg retina angiograph 2, Heidelberg Engineering, Dossenheim, Germany) w...

متن کامل

Lower limits of fluorescein and indocyanine green dye for digital cSLO fluorescence angiography.

BACKGROUND With the advent of digital confocal scanning laser ophthalmoscopy it is possible to detect low levels of fluorescence. Here we used a novel confocal scanning laser ophthalmoscope (cSLO) to determine lower limits of dye required for fluorescein (FL) and indocyanine green (ICG) angiography. METHODS A cSLO (Heidelberg retina angiograph 2, Heidelberg Engineering, Dossenheim, Germany) w...

متن کامل

[Simultaneous digital indocyanine green and fluorescein angiography].

BACKGROUND The simultaneous recording of indocyanine green and fluorescein angiography is since more than twenty years possible. The real-time digital recording of angiograms is about since 10 years possible. Because of the poor temporal resolution due to technical limitations, both of the above methods were only seldom used routinely. Graphics workstations can digitize and store multiple video...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Klinische Monatsblatter fur Augenheilkunde

دوره 216 5  شماره 

صفحات  -

تاریخ انتشار 2000