Wavelength optimization for rapid chromophore mapping using spatial frequency domain imaging.

نویسندگان

  • Amaan Mazhar
  • Steven Dell
  • David J Cuccia
  • Sylvain Gioux
  • Anthony J Durkin
  • John V Frangioni
  • Bruce J Tromberg
چکیده

Spatial frequency-domain imaging (SFDI) utilizes multiple-frequency structured illumination and model-based computation to generate two-dimensional maps of tissue absorption and scattering properties. SFDI absorption data are measured at multiple wavelengths and used to fit for the tissue concentration of intrinsic chromophores in each pixel. This is done with a priori knowledge of the basis spectra of common tissue chromophores, such as oxyhemoglobin (ctO(2)Hb), deoxyhemoglobin (ctHHb), water (ctH(2)O), and bulk lipid. The quality of in vivo SFDI fits for the hemoglobin parameters ctO(2)Hb and ctHHb is dependent on wavelength selection, fitting parameters, and acquisition rate. The latter is critical because SFDI acquisition time is up to six times longer than planar two-wavelength multispectral imaging due to projection of multiple-frequency spatial patterns. Thus, motion artifact during in vivo measurements compromises the quality of the reconstruction. Optimal wavelength selection is examined through matrix decomposition of basis spectra, simulation of data, and dynamic in vivo measurements of a human forearm during cuff occlusion. Fitting parameters that minimize cross-talk from additional tissue chromophores, such as water and lipid, are determined. On the basis of this work, a wavelength pair of 670 nm∕850 nm is determined to be the optimal two-wavelength combination for in vivo hemodynamic tissue measurements provided that assumptions for water and lipid fractions are made in the fitting process. In our SFDI case study, wavelength optimization reduces acquisition time over 30-fold to 1.5s compared to 50s for a full 34-wavelength acquisition. The wavelength optimization enables dynamic imaging of arterial occlusions with improved spatial resolution due to reduction of motion artifacts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatial frequency domain imaging of burn wounds in a preclinical model of graded burn severity.

Frequent monitoring of early-stage burns is necessary for deciding optimal treatment and management. Both superficial and full thickness burns are relatively easy to diagnose based on clinical observation. In between these two extremes are superficial-partial thickness and deep-partial thickness burns. These burns, while visually similar, differ dramatically in terms of clinical treatment and a...

متن کامل

High-speed spatial frequency domain imaging with temporally modulated light.

Spatial frequency domain imaging (SFDI) is a wide-field diffuse optical technique used to obtain optical properties and chromophore concentrations in highly scattering media, such as biological tissue. Here, we present a method for rapidly acquiring multispectral SFDI data by modulating each illumination wavelength at a different temporal frequency. In the remitted signal, each wavelength is te...

متن کامل

Quantitative assessment of renal arterial occlusion in a porcine model using spatial frequency domain imaging.

We present the results of a feasibility study with spatial frequency domain imaging (SFDI) to produce quantitative measurements of optical property and chromophore concentration maps of three porcine kidneys utilizing a renal occlusion model at the near-infrared wavelengths of 658, 730, and 850 nm. Using SFDI, we examined the dynamics of absolute oxygen saturation (StO2). The mean StO2 for the ...

متن کامل

Convergence Analysis and Preliminary Experimental Feasibility for MRI-Localized Region Spectroscopy with NIR Diffuse Optical Tomography

NIR tomography image reconstruction can be improved by incorporating spectral constraints and prior spatial information. The convergence of scattering power was studied based on the distribution of projection error with different parameters. The reason that scattering properties are harder to recover than chromophore concentrations was discussed. Using “hard prior” spectral reconstruction, the ...

متن کامل

Attenuation of spatial aliasing in CMP domain by non-linear interpolation of seismic data along local slopes

Spatial aliasing is an unwanted side effect that produces artifacts during seismic data processing, imaging and interpolation. It is often caused by insufficient spatial sampling of seismic data and often happens in CMP (Common Mid-Point) gather. To tackle this artifact, several techniques have been developed in time-space domain as well as frequency domain such as frequency-wavenumber, frequen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2010