Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study
نویسندگان
چکیده
BACKGROUND Locking compress plate, as external fixator, is an attractive technique for distal tibial fracture treatment. But it still remains unclear whether the external LCP has sufficient stiffness. Thus, the present study aims to make a comprehensive evaluation of the stiffness of external locking compress plate when it is used as an external fixator in distal tibial fractures treatment. METHODS Composite tibia was used to simulate distal tibia fracture (Orthopedic Trauma Association type 43 A3 fracture). The fractures were stabilized with medial distal tibial locking compress plates (LCP group), medial distal tibial locking compress plates with 30-mm plate-bone distances (EF-tibia group), and medial distal femur locking compress plates with 30-mm plate-bone distances (EF-femur group). Stiffness of each configuration was measured under axial compression loading and in axial torsion loading directions. Compression stiffness and torsional rigidity were compared across different groups. RESULTS Compared with LCP group, (1) EF-tibia group showed significantly lower (p < 0.001) compression stiffness and torsional rigidity; (2) EF-femur group showed significantly lower (p < 0.001) compression stiffness, but significantly higher (p < 0.001) torsional rigidity. CONCLUSIONS The results indicated that locking compress plate as an external fixator was flexible, and the distal femur locking compress plate was preferred over the distal tibial locking compress plate to be an external fixator in distal tibia fracture treatment.
منابع مشابه
Locked plating as an external fixator in treating tibial fractures
OBJECTIVES This article is a systematic review of the published literature about the biomechanics, functional outcomes, and complications of a locked plate as an external fixator in treating tibial fractures. METHODS We searched the PubMed, Ovid Medline, Embase, ScienceDirect, and Cochrane Library databases to retrieve the relevant studies. Studies published in English and Chinese which asses...
متن کاملDilemmas in the treatment of tibial diaphyseal fractures.
INTRODUCTION Tibial fractures accompanied by radius fractures at typical sites are the most common type of fractures. OBJECTIVE The study is aimed at using the examined sample to make an efficient and economically acceptable choice in the treatment of tibial diaphyseal fractures. MATERIAL AND METHODS The series comprises a retrospective and prospective study of the treatment of 131 fresh ti...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملUnstable proximal extraarticular tibia fractures: a biomechanical evaluation of four methods of fixation.
OBJECTIVE To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. DESIGN Standardized proximal tibial fractures (AO classification 41-A3.2 and A3.3) in synthetic tibiae were stabilized using one of the fo...
متن کاملEvaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.
PURPOSE To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. METHODS A simulated, unstable, extra- articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator [Mirza Cross Pin Fixator (CPX)...
متن کامل