Weak Values from Displacement Currents in Multiterminal Electron Devices.

نویسندگان

  • D Marian
  • N Zanghì
  • X Oriols
چکیده

Weak values allow the measurement of observables associated with noncommuting operators. Up to now, position-momentum weak values have been mainly developed for (relativistic) photons. In this Letter, a proposal for the measurement of such weak values in typical electronic devices is presented. Inspired by the Ramo-Shockley-Pellegrini theorem that provides a relation between current and electron velocity, it is shown that the displacement current measured in multiterminal configurations can provide either a weak measurement of the momentum or strong measurement of position. This proposal opens new opportunities for fundamental and applied physics with state-of-the-art electronic technology. As an example, a setup for the measurement of the Bohmian velocity of (nonrelativistic) electrons is presented and tested with numerical experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First-principles methodology for quantum transport in multiterminal junctions.

We present a generalized approach for computing electron conductance and I-V characteristics in multiterminal junctions from first-principles. Within the framework of Keldysh theory, electron transmission is evaluated employing an O(N) method for electronic-structure calculations. The nonequilibrium Green function for the nonequilibrium electron density of the multiterminal junction is computed...

متن کامل

ZnO tetrapods designed as multiterminal sensors to distinguish false responses and increase sensitivity.

Individual zinc oxide tetrapods were designed as multiterminal sensors by the e-beam lithography method. Different from double-terminal sensors, these sensors can give multiple responses to a single signal at the same time. The designed tetrapod devices were employed to detect light with different wavelength. The results indicate that they are remarkable optoelectronic devices, sensitive to ult...

متن کامل

High-quality multiterminal suspended graphene devices.

We introduce a new scheme to realize suspended, multiterminal graphene structures that can be current annealed successfully to obtain uniform, very high quality devices. A key aspect is that the bulky metallic contacts are not connected directly to the part of graphene probed by transport measurements, but only through etched constriction, which prevents the contacts from acting invasively. The...

متن کامل

A. Solutions to the Problem of the Optimum Noise Performance of Multiterminal Amplifiers

The research on noise in electron devices has two objectives: (i) The study of specific devices, such as the parametric amplifier and the maser, to determine the physical sources of noise and the limitations they impose on the noise performance of the amplifier. The parametric amplifier with coherent input signals at both the signal and idler frequency, and the degenerate parametric amplifier a...

متن کامل

Why Should We Have a Periodic Safety and Performance Program for Medical Devices

Nowadays, more than 10,000 different types of medical devices can be found in hospitals.These devices used in medical centers and hospitals for monitoring and treatment of patients require periodic safety and performance checking in order to have confidence in their functioning and operation. Physicians need better accurate medical measurements in order to better diagnose diseases, monitor pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 116 11  شماره 

صفحات  -

تاریخ انتشار 2016