NBS/NIST Gas Thermometry From 0 to 660 °C

نویسنده

  • J. F. Schooley
چکیده

In the NBS/NIST Gas Thermometry program, constant-volume gas thermometers, a unique mercury manometer, and a highly accurate thermal expansion apparatus have been employed to evaluate temperatures on the Kelvin Thermodynamic Temperature Scale (KTTS) that correspond to particular temperatures on the 1968 International Practical Temperature Scale (IPTS-68). In this paper, we present a summary of the NBS/NIST Gas Thermometry project, which originated with planning activities in the late 1920s and was completed by measurements of the differences t(KTTS)-t(IPTS-68) in the range 0 to 660 °C. Early results of this project were the first to demonstrate the surprisingly large inaccuracy of the IPTS-68 with respect to the KTTS above 0 °C. Advances in several different measurement techniques, development of new, specialized instruments, and two distinct sets of gas thermometry observations have resulted from the project.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Summary of Lightpipe Radiation Thermometry Research at NIST

During the last 10 years, research in light-pipe radiation thermometry has significantly reduced the uncertainties for temperature measurements in semiconductor processing. The National Institute of Standards and Technology (NIST) has improved the calibration of lightpipe radiation thermometers (LPRTs), the characterization procedures for LPRTs, the in situ calibration of LPRTs using thin-film ...

متن کامل

The Reduction of Uncertainties for Absolute Piston Gage Pressure Measurements in the Atmospheric Pressure Range

NIST pressure calibration services with nitrogen are now based on two transfer standard piston gages for which the effective areas have been determined by calibration with the manometer developed at NIST for gas thermometry. Root-sum-squared three sigma uncertainties for the areas for the two gages are 3.05 ppm and 4.18 ppm.

متن کامل

The Kelvin and Temperature Measurements

The International Temperature Scale of 1990 (ITS-90) is defined from 0.65 K upwards to the highest temperature measurable by spectral radiation thermometry, the radiation thermometry being based on the Planck radiation law. When it was developed, the ITS-90 represented thermodynamic temperatures as closely as possible. Part I of this paper describes the realization of contact thermometry up to ...

متن کامل

Nist Certification of Its-90 Fixed-point Cells from 83.8058 K to 1234.93 K: Methods and Uncertainties

The certification of ITS-90 fixed-point cells from the Ar triple point (83.8058 K) to the Ag freezing point (1234.93 K) is an integral part of the calibration services offered by the NIST Thermometry Group. This service is used to qualify new fixed-point cells for internal use within the NIST Thermometry Group and by those facilities seeking traceability to NIST for the ITS-90 calibration of SP...

متن کامل

NIST Mechanisms for Disseminating Measurements

The national responsibilities assigned to the National Bureau of Standards (NBS) early in the last century for providing measurement assistance and service are carried out today by the four programs that comprise the National Institute of Standards and Technology (NIST) Office of Measurement Services (OMS). They are the Calibration Program (CP), the Standard Reference Materials Program (SRMP), ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 1990