Long-term histological and electrophysiological results of an inactive epiretinal electrode array implantation in dogs.
نویسندگان
چکیده
PURPOSE Short-term pattern electrical stimulation of the retina via multielectrode arrays in humans blind from photoreceptor loss has shown that ambulatory vision and limited character recognition is possible. To develop an implantable retinal prosthesis that would provide useful vision, these results need to be sustained over a prolonged period of retinal electrical stimulation. As a first step toward this goal, the biocompatibility and the feasibility of surgically implanting an electrically inactive electrode array onto the retinal surface was tested. METHODS A 5 x 5 electrode array (25 platinum disc-shaped electrodes in a silicone matrix) was implanted onto the retinal surface using retinal tacks in each of the 4 mixed-breed sighted dogs. Color fundus photography, fluorescein angiography, electroretinography, and visual evoked potentials were obtained preoperatively, at 1-week intervals for 2 weeks postoperatively, then at 2-week intervals up to 2 months postoperatively, and thereafter at 1-month intervals. One dog was killed at 2 months after implantation and a second dog after 3 months of implantation. Histologic evaluation of the retinas was performed. The remaining two dogs continue to be followed beyond 6 months after the implantation surgery. RESULTS No retinal detachment, infection, or uncontrolled intraocular bleeding occurred in any of the animals. Retinal tacks and the retinal array remained firmly affixed to the retina throughout the follow-up period. Hyperpigmentation of the retinal pigment epithelium was observed only around the site of retinal tack insertion. No fibrous encapsulation of the implant or intraocular inflammation was visible. A- and b-wave amplitudes of the electroretinogram were depressed at the first postoperative week testing but recovered over the ensuing 1 week and were not statistically different from the normal unoperated fellow eye throughout the postoperative period. N1 and P1 wave amplitudes of the visual evoked potentials were not significantly different from the normal fellow eyes at any of the postoperative test intervals. Fluorescein angiography showed that the entire retina including the area under the electrode array remained well perfused. Similarly, histologic evaluation revealed near total preservation of the retina underlying the electrode array. CONCLUSIONS Implantation of an electrode array on the epiretinal side (i.e., side closest to the ganglion cell layer) is surgically feasible, with insignificant damage to the underlying retina. The platinum and silicone arrays as well as the metal tacks are biocompatible. With the success of implanting an electrically inactive device onto the retinal surface for prolonged periods, the effects of long-term retinal electrical stimulation are now ready to be tested as the next step toward developing a prototype retinal prosthesis for human use.
منابع مشابه
Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملImplantation of multiple suprachoroidal electrode arrays in rabbits
Purpose Epiretinal and subretinal prosthesis have been shown to be a valid way to provide some vision to patients with advanced outer retinal degeneration and profound vision loss. However, the field of vision for these patients is markedly limited by the area occupied by the electrode array. In this study, we aimed to evaluate the feasibility of implantation of multiple suprachoroidal electrod...
متن کاملMulti-electrode arrays technology for the non-invasive recording of neural signals: a review article
The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...
متن کاملMorphometric analysis of optic nerves and retina from an end-stage retinitis pigmentosa patient with an implanted active epiretinal array.
PURPOSE To characterize optic nerve and retinal changes in a patient with end-stage retinitis pigmentosa (RP) with an implanted active epiretinal array. METHODS A 74-year-old man with end-stage X-linked RP underwent implantation of an epiretinal array over the macula in the right eye and subsequent stimulation until his death at 5 years and 3 months after implantation. The optic nerves from t...
متن کاملFeasibility study of a retinal prosthesis: spatial vision with a 16-electrode implant.
OBJECTIVE To demonstrate that an epiretinal prosthesis can produce patterned visual perception in patients blinded by photoreceptor degeneration who have no other treatment options. METHODS A totally blind subject with retinitis pigmentosa had a 16-electrode epiretinal prosthesis implanted. The implant is controlled wirelessly by an external computer or a head-mounted video camera. Spatial vi...