Simultaneous multi-depth assessment of tissue oxygen saturation in thenar and forearm using near-infrared spectroscopy during a simple cardiovascular challenge
نویسندگان
چکیده
INTRODUCTION Hypovolemia and hypovolemic shock are life-threatening conditions that occur in numerous clinical scenarios. Near-infrared spectroscopy (NIRS) has been widely explored, successfully and unsuccessfully, in an attempt to use it as an early detector of hypovolemia by measuring tissue oxygen saturation (StO2). In order to investigate the measurement site dependence and probe dependence of NIRS in response to hemodynamic changes, such as hypovolemia, we applied a simple cardiovascular challenge: a posture change from supine to upright, causing a decrease in stroke volume (as in hypovolemia) and a heart rate increase in combination with peripheral vasoconstriction to maintain adequate blood pressure. METHODS Multi-depth NIRS was used in nine healthy volunteers to assess changes in StO2 in the thenar and forearm in response to the hemodynamic changes associated with a posture change from supine to upright. RESULTS A posture change from supine to upright resulted in a significant increase (P < 0.001) in heart rate. Thenar StO2 did not respond to the hemodynamic changes following the posture change, whereas forearm StO2 did. Forearm StO2 was significantly lower (P < 0.001) in the upright position compared to supine for all probing depths. CONCLUSIONS The primary findings in this study were that forearm StO2 is a more sensitive parameter to hemodynamic changes than thenar StO2 and that the depth at which StO2 is measured is of minor influence. Our data support the use of forearm StO2 as a sensitive parameter for the detection of central hypovolemia and hypovolemic shock in (trauma) patients.
منابع مشابه
Oxygen saturation determined from deep muscle, not thenar tissue, is an early indicator of central hypovolemia in humans.
OBJECTIVE To compare the responses of noninvasively measured tissue oxygen saturation (StO2) and calculated muscle oxygen tension (PmO2) to standard hemodynamic variables for early detection of imminent hemodynamic instability during progressive central hypovolemia in humans. DESIGN Prospective study. SETTING Research laboratory. SUBJECTS Sixteen healthy human volunteers. INTERVENTIONS ...
متن کاملNear infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care
Near infrared spectroscopy of the thenar eminence (NIRSth) is a noninvasive bedside method for assessing tissue oxygenation. The NIRS probe emits light with several wavelengths in the 700- to 850-nm interval and measures the reflected light mainly from a predefined depth. Complex physical models then allow the measurement of the relative concentrations of oxy and deoxyhemoglobin, and thus tissu...
متن کاملCardiac troponin and skeletal muscle oxygenation in severe post-partum haemorrhage
INTRODUCTION Cardiac troponin has been shown to be elevated in one-half of the parturients admitted for post-partum haemorrhage. The purpose of the study was to assess whether increased cardiac troponin was associated with a simultaneous alteration in haemoglobin tissue oxygen saturation in peripheral muscles in post-partum haemorrhage. METHODS Tissue haemoglobin oxygen saturation of thenar e...
متن کاملAssessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers
INTRODUCTION To assess potential metabolic and microcirculatory alterations in critically ill patients, near-infrared spectroscopy (NIRS) has been used, in combination with a vascular occlusion test (VOT), for the non-invasive measurement of tissue oxygen saturation (StO2), oxygen consumption, and microvascular reperfusion and reactivity. The methodologies for assessing StO2 during a VOT, howev...
متن کاملEffect of Skin Pigmentation on Near Infrared Spectroscopy
The purpose of this study was to determine the effects of skin pigmentation regarding Near Infrared Spectroscopy (NIRS) tissue oxygen saturation values (StO2). The study examined NIRS values in individuals with varying skin pigmentation on the anterior compartment of the lower leg and volar forearm to determine if correlation exists among three NIRS devices, the EQUANOX, Casmed, and INVOS. Skin...
متن کامل