Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen.

نویسندگان

  • Zong Dai
  • Feng Yan
  • Hua Yu
  • Xiaoya Hu
  • Huangxian Ju
چکیده

A novel immunosensor for rapid separation-free determination of carcinoembryonic antigen (CEA) in human serum is proposed. The immunosensor is prepared by co-immobilizing thionine and horseradish peroxidase (HRP)-labeled CEA antibody on a glassy carbon electrode (GCE) through covalently binding them to GCE with a glutaraldehyde (GA) linkage. The electrochemical behavior of the immobilized thionine displays a surface-controlled electrode process with an average electron transfer rate constant of 4.74+/-2.99 s(-1). It can be used as an electron transfer mediator for enzymatic activity detection of the HRP-labeled antibody to CEA. After the immunosensor is incubated with CEA solution at 23 degrees C for 40 min, the access of activity center of the HRP to thionine is partly inhibited, which leads to a linear decrease in the catalytic efficiency of the HRP to the oxidation of immobilized thionine by H(2)O(2) at -300 mV over two CEA concentration ranges from 0.5 to 3.0 and 3.0 to 167 ng/ml. Under optimal conditions, the detection limit for the CEA immunoassay is 0.1 ng/ml at three times background noise. The immunosensor shows good accuracy and acceptable storage stability, precision and reproducibility with intra-assay CVs of 6.1% and 5.8% at 2.5 and 50 ng/ml CEA, respectively, and an inter-assay CV of 6.3% at 50 ng/ml. This method is economical and shortens the analytical time, making it potentially attractive for clinical immunoassays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A sensitive label-free amperometric CEA immunosensor based on graphene-nafion nanocomposite film as an enhanced sensing platform.

A novel approach to fabricate a label-free amperometric immunosensor for the detection of carcinoembryonic antigen (CEA) was described. Herein, methylene blue (MB), gold nanoparticles (AuNPs) and carcinoembryonic antibody (anti-CEA) were layer-by-layer assembled on the graphene-Nafion nanocomposite film-modified electrode by means of a self-assembling technique and the opposite-charged adsorpti...

متن کامل

A chitosan-Au-hyperbranched polyester nanoparticles-based antifouling immunosensor for sensitive detection of carcinoembryonic antigen.

Analysts are always interested in finding new functional nanomaterials and devices with good properties for electrochemical sensor applications. In this paper, hyperbranched polyester nanoparticles with carboxylic acid functional groups (HBPE-CA NPs) were synthesized and combined with chitosan wrapped around Au nanoparticles (CS-Au NPs) to prepare a novel and sensitive electrochemical immunosen...

متن کامل

A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers.

BACKGROUND Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. METHODS We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetopr...

متن کامل

Electrochemical immunosensor for carcinoembryonic antigen based on antigen immobilization in gold nanoparticles modified chitosan membrane.

A disposable electrochemical immunosensor for carcinoembryonic antigen (CEA) was proposed based on the antigen immobilized in a colloidal gold nanoparticles modified chitosan membrane on the surface of an indium-tin oxide (ITO) electrode. The different membranes were characterized by scanning electron microscope and electrochemical methods. Based on a competitive immunoassay format, the immobil...

متن کامل

Polymerization-assisted signal amplification for electrochemical detection of biomarkers.

We present a novel immunosensor by using polymerization-assisted signal amplification strategy coupled with electrochemical detection. A sandwich immunoassay process was used to immobilize a polymerization reaction center, the initiator-conjugated polyclonal prostate specific antigen (PSA) or polyclonal carcinoembryonic antigen (CEA) antibodies on the surface of the electrode. Activator generat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of immunological methods

دوره 287 1-2  شماره 

صفحات  -

تاریخ انتشار 2004