Efficacy and safety of hypromellose in ocular implant surgery.

نویسندگان

  • P A Rosen
  • A M Brooks
  • R J Ramsay
  • K P Gullifer
  • R J Wolfe
  • W E Gillies
چکیده

In order to assess the efficacy of hypromellose as a viscoelastic substance in cataract surgery with posterior chamber intraocular lens implantation, we studied a series of 88 cases who underwent surgery with either alternate use of a viscoelastic substance (hypromellose, 39 patients, or sodium hyaluronate, 5 patients) or air (44 patients) in the anterior chamber. Endothelial cell loss was least in the group in which air was used (18 +/- 3% cell loss, mean +/- SEM), compared with hypromellose (26 +/- 3%) and sodium hyaluronate (28 +/- 6%), but the difference in percentage cell loss between the groups did not reach statistical significance. Some operative difficulties were encountered in both groups. In both the air and hypromellose groups there were two patients with an early postoperative rise in intraocular pressure, but this was easily controlled, and in both groups there were two patients with postoperative corneal oedema which soon cleared. Visco-elastic substances used in this study were not shown to be superior to air in protecting the corneal endothelium. For this reason use of hypromellose should be confined to situations where its use is likely to confer some special advantage, as in the presence of a bound-down pupil in patient's with chronic glaucoma or perhaps to facilitate "in the bag" implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and efficacy of 2% methylcellulose in cat and monkey cataract-implant surgery.

We evaluated the safety and efficacy of 2% methycellulose as an adjunct for cataract extraction with implantation in cat and monkey models. When used intraoperatively, methylcellulose reduced the iridovitreal bulge during surgery. No significant increase in clinical inflammation occurred nor was there statistically significant intraocular pressure elevation at 24 hours, 7 days, or 90 days. In t...

متن کامل

Evaluation of ocular hydroxyapatite implant with Tc-99m MDP bone scan [Persian]

Static bone scan was performed in 46 patients for evaluation of ocular Hydroxyapatite Vascularization. Study Findings indicated that bone scan, with TC-99m MDP is an appropriate method for evaluation of Hydroxyapatite Vascularization and for estimating the time For peg insertion into the Hydroxyapatite implant. Our study showed proper Hydroxyapatite Vascularization when the ratio of activ...

متن کامل

Comparison of hyaluronic acid-containing topical eye drops with carbomer-based topical ocular gel as a tear replacement in canine keratoconjunctivitis sicca: A prospective study in twenty five dogs

The aim of this study was to evaluate the efficacy of a hyaluronic acid containing eye drop in ameliorating ocular surface pathology and discomfort in canine keratoconjunctivitis sicca (KCS). Twenty five dogs with KCS treated with a topical carbomer (CA)-based tear replacement gel were moved to treatment with a hyaluronic acid (HA)-containing tear replacement eye drop. Dogs were subject to a fu...

متن کامل

An Investigation of Safety and Efficacy of Intravenous Paracetamol in Pain Management Following Cardiac Surgery

Introduction: Optimum pain management immediately after surgeries can lower the possibility of pain syndrome and its following consequences. Opioids are amongst the analgesics used for postoperative pain control; however, their application can bring about several adverse effects. In this study, all the published articles regarding efficacy of Paracetamol   in post-cardiac surgery pain managemen...

متن کامل

Multipurpose conical orbital implant in evisceration.

PURPOSE To evaluate the safety and efficacy of the porous polyethylene multipurpose conical orbital implant for use in evisceration. METHODS A retrospective review of 31 eyes that underwent evisceration and received the multipurpose conical orbital implant. The orbits were evaluated at 1 week, 1 month, and 6 months after final prosthetic fitting for implant exposure, superior sulcus deformity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Australian and New Zealand journal of ophthalmology

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 1987